Olympia, WA zoning: where a drive-thru restaurant is allowed
Is a drive-thru allowed in Olympia, WA?
A drive-thru restaurant is allowed by right (no conditional use permit, special exception or rezoning) in these zoning districts: GC, I, LI, UV.
It is not allowed in 27 districts (mostly residential; see the table).
5 districts are not confirmed yet.
Drive-thru rules in plain words
New drive-through restaurants are allowed by right in General Commercial (with layout rules on pedestrian-oriented streets), Light Industrial/Commercial and Industrial (20,000 sq ft cap), and in Urban Village with a single lane for restaurants that mainly serve walk-in customers. In HDC-2 and HDC-3 a restaurant may only use a building that already has a drive-through, and Downtown Business, Urban Waterfront, residential and most other commercial districts bar new ones. HDC-1 and HDC-4 are unclear because the use table could not be lined up (one reads conditional or blank, the other blank or permitted).
Code facts
- Jurisdiction
- City of Olympia
- Zoning code
- Olympia Municipal Code Title 18, Unified Development Code
- Code last amended
- Chapter 18.06 header reads revised 9/24
- Restaurant parking
- Fast food: 10 spaces per 1,000 sq ft plus 1 lane for each drive-up window. Other eating and drinking places: 10 spaces per 1,000 sq ft (OMC 18.38, Table 38.01).
- Drive-thru stacking
- Fast-food drive-up window: 1 lane per window with stacking space for 6 vehicles before the menu board (OMC 18.38.100, Table 38.01).
- Official code
- codepublishing.com
- Planning office
- City of Olympia Community Planning & Economic Development olympiawa.gov
District standards
| District | Name | Restaurant | Retail | Grocery | Section |
|---|---|---|---|---|---|
| AS | Auto Services | By right | Not allowed | Not allowed | 18.06.040 Table 6.01 source |
| COSC | Community Oriented Shopping Center | By right | 18.05.040 Table 5.01 source | ||
| CS-H | Commercial Services-High Density | By right | Not allowed | By right | 18.06.040 Table 6.01 source |
| DB | Downtown Business | By right | By right | By right | 18.06.060(F)(2), (U)(1) source |
| GC | General Commercial | By right | By right | By right | 18.06.040 Table 6.01 source |
| HDC-1 | High Density Corridor-1 | By right | By right | By right | 18.06.040 Table 6.01; 18.06.060(F)(1), (H), (J) source |
| HDC-2 | High Density Corridor-2 | By right | By right | By right | 18.06.040 Table 6.01; 18.06.060(F)(1) source |
| HDC-3 | High Density Corridor-3 | By right | By right | By right | 18.06.040 Table 6.01; 18.06.060(F)(1), (F)(3) source |
| HDC-4 | High Density Corridor-4 | By right | By right | By right | 18.06.040 Table 6.01 source |
| I | Industrial | By right | By right | Not allowed | 18.08.040 Table 8.01; 18.08.080(F) source |
| LI | Light Industrial/commercial | By right | By right | Not allowed | 18.08.040 Table 8.01 source |
| MS | Medical Service(s) | Conditional | Not allowed | Not allowed | 18.06.040 Table 6.01 source |
| NC | Neighborhood Center | By right | 18.05.040 Table 5.01 source | ||
| NR | Neighborhood Retail | By right | By right | By right | 18.06.040 Table 6.01 source |
| NV | Neighborhood Village | By right | 18.05.040 Table 5.01 source | ||
| PO/RM | Professional Office/Residential Multifamily | Conditional | By right | By right | 18.06.040 Table 6.01; 18.06.060(H), (J) source |
| UV | Urban Village | By right | 18.05.040 Table 5.01 source | ||
| UW | Urban Waterfront | By right | By right | By right | 18.06.060(F)(2) source |
| UWH | Urban Waterfront-Housing | By right | By right | By right | 18.06.040 Table 6.01 source |
Second check against the source text: 2026-11-29 (Escalation read of 18.06.040 Table 6.01, 18.06.060(D),(F),(U),(Y), 18.05.040/060, 18.08.060/080. Table 6.01 new drive-through row read as 13 lines: GC=P(F)(3), two C(F)(1) and one P(F)(3) at the HDC end; alignment HDC-1/2/3 vs HDC-2/3/4 cannot be fixed from flattened text. HDC-2 and HDC-3 set prohibited (new) on the explicit text of 18.06.060(F)(1); HDC-1 and HDC-4 left unclear; HDC-4 changed from prohibited to unclear. I and LI/C confirmed by_right from 18.08.080(F)(1)(c) and 18.08.060(B)(1)(c). UV raised to medium from 18.05.060(A)(1) text. Blank-cell districts now quote 18.06.040(B). Added Thurston County zoning layer (Olympia filter) and CAP/PUD districts. Profile restaurant column corrected to non-drive-through restaurant status. Fetch tool would not give the table verbatim; codepublishing html0322 copy could not be fetched.).
Drive-thru restaurant rule by zoning district
| District | Drive-thru restaurant | What the code says | Section | Source | Read on |
|---|---|---|---|---|---|
| AS Auto Services | Not allowed | Land uses which are not listed as permitted or conditional uses are prohibited unless authorized Table 6.01 drive-through restaurant row: this column is blank in every reading (the blank run between GC and the HDC columns), and 18.06.040(B) prohibits unlisted uses. Restaurants without a drive-through are permitted; service stations and car washes are allowed here. | 18.06.040(B), Table 6.01 | codepublishing.com | 2026-11-29 |
| CAP Capitol Campus | Not confirmed | Not read closely enough to state a rule. | tconline.co.thurston.wa.us | 2026-11-29 | |
| CMR Community Retail | Not confirmed | Not read closely enough to state a rule. | codepublishing.com | 2026-11-29 | |
| COSC Community Oriented Shopping Center | Not allowed | Land uses which are not listed in Table 5.01 as permitted, conditional, or required uses are prohibited Only the Table 5.01 row 'Restaurants, Without Drive-In or Drive-Through Service' is P here; the restaurant row allowing a single drive-through lane (18.05.060(A)) is P only in Urban Village. | 18.05.040(B), Table 5.01 | codepublishing.com | 2026-11-29 |
| CS-H Commercial Services-High Density (written CSH in the code) | Not allowed | Land uses which are not listed as permitted or conditional uses are prohibited unless authorized Table 6.01 drive-through restaurant row: this column is blank in every reading (the blank run between GC and the HDC columns), and 18.06.040(B) prohibits unlisted uses. Restaurants without a drive-through are permitted. Map layer codes this district CS-H. | 18.06.040(B), Table 6.01 | codepublishing.com | 2026-11-29 |
| DB Downtown Business | Not allowed | Drive-through and drive-in uses are prohibited as a primary or accessory use. New drive-in and drive-through restaurants are not permitted. Drive-through banks are conditional. Pre-1994 existing restaurants are conforming. | 18.06.060(F)(2); 18.06.060(U)(1) | codepublishing.com | 2026-11-29 |
| GC General Commercial | By right | Drive-through and drive-in uses are allowed on parcels that abut pedestrian oriented streets, as follows: Table 6.01 shows P (citing 18.06.060(F)(3)) in the GC column in every reading; GC is the third column after two blank cells, so its position is not in doubt. The GC purpose statement favours uses dependent on vehicle access. Where the parcel abuts a pedestrian-oriented A street, a building or plaza (with bollards/curbs keeping cars out) must sit between the drive-through and the street; on B streets the lane cannot run between street and building. Stacking: 6 cars per window (18.38.100). | 18.06.040 Table 6.01; 18.06.060(F)(3) | codepublishing.com | 2026-11-29 |
| HDC-1 High Density Corridor-1 | Not confirmed | Not read closely enough to state a rule. | codepublishing.com | 2026-11-29 | |
| HDC-2 High Density Corridor-2 | Not allowed | Restaurants are only permitted to have drive-up or drive-through facilities if the building has existing drive through facilities 18.06.060(F)(1), titled for HDC-2 and HDC-3, allows a restaurant drive-up/drive-through only in a building that already has drive-through facilities, meeting fast-food stacking in 18.38.100; businesses serving customers only in vehicles are prohibited. So no new drive-through building; re-using an existing drive-through building is allowed (table shows C, i.e. conditional use permit, in the likely alignment). Recorded prohibited for a new drive-thru on the text, which is explicit. | 18.06.060(F)(1); 18.06.040 Table 6.01 | codepublishing.com | 2026-11-29 |
| HDC-3 High Density Corridor-3 | Not allowed | Restaurants are only permitted to have drive-up or drive-through facilities if the building has existing drive through facilities 18.06.060(F)(1), titled for HDC-2 and HDC-3, allows a restaurant drive-up/drive-through only in a building that already has drive-through facilities, meeting stacking in 18.38.100; vehicle-only businesses are prohibited, and drive-through retail windows are barred (18.06.060(Y)(1)). The table cell (C or P depending on alignment) does not override this. Re-use of an existing drive-through building is allowed; a new drive-through building is not. | 18.06.060(F)(1); 18.06.060(Y)(1); 18.06.040 Table 6.01 | codepublishing.com | 2026-11-29 |
| HDC-4 High Density Corridor-4 | Not confirmed | Not read closely enough to state a rule. | codepublishing.com | 2026-11-29 | |
| I Industrial | By right | Restaurants and drinking establishments, including drive-ins. Table 8.01 shows P but cites 18.08.080(B), which actually regulates off-site hazardous waste facilities (cross-reference error); the commercial-use list is 18.08.080(F). 20,000 sq ft cap per commercial use, except none on the Port Peninsula north of A Avenue. Stacking and parking in 18.38 apply. | 18.08.040 Table 8.01; 18.08.080(F)(1)(c), (F)(2) | codepublishing.com | 2026-11-29 |
| LI Light Industrial/commercial (written LI/C in the code) | By right | Restaurants and drinking establishments, including drive-ins. Table 8.01 shows P citing 18.08.060(B). Commercial uses must not significantly interfere with industrial uses; any single commercial use is capped at 20,000 sq ft gross floor area. Stacking and parking rules in 18.38 apply. The map layer codes this district LI. | 18.08.040 Table 8.01; 18.08.060(B)(1)(c), (B)(2) | codepublishing.com | 2026-11-29 |
| MHP Manufactured Housing Park | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| MR 7-13 Mixed Residential 7-13 Units per Acre | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| MR 10-18 Mixed Residential 10-18 Units per Acre | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| MS Medical Service(s) | Not allowed | Land uses which are not listed as permitted or conditional uses are prohibited unless authorized Table 6.01 drive-through restaurant row: this column is blank in every reading (the blank run between GC and the HDC columns), and 18.06.040(B) prohibits unlisted uses. Restaurants without a drive-through may be a conditional use if they mainly serve the medical community (18.06.060(U)(2)). | 18.06.040(B), Table 6.01 | codepublishing.com | 2026-11-29 |
| NC Neighborhood Center | Not allowed | Land uses which are not listed in Table 5.01 as permitted, conditional, or required uses are prohibited Only the Table 5.01 row 'Restaurants, Without Drive-In or Drive-Through Service' is P here; the restaurant row allowing a single drive-through lane (18.05.060(A)) is P only in Urban Village. | 18.05.040(B), Table 5.01 | codepublishing.com | 2026-11-29 |
| NR Neighborhood Retail | Not allowed | Land uses which are not listed as permitted or conditional uses are prohibited unless authorized Table 6.01 drive-through restaurant row: this column is blank in every reading (the blank run between GC and the HDC columns), and 18.06.040(B) prohibits unlisted uses. Restaurants without a drive-through are permitted, limited to 1,000 sq ft and no Type I hood (18.06.060(U)(3)). | 18.06.040(B), Table 6.01 | codepublishing.com | 2026-11-29 |
| NV Neighborhood Village | Not allowed | Land uses which are not listed in Table 5.01 as permitted, conditional, or required uses are prohibited Only the Table 5.01 row 'Restaurants, Without Drive-In or Drive-Through Service' is P here; the restaurant row allowing a single drive-through lane (18.05.060(A)) is P only in Urban Village. | 18.05.040(B), Table 5.01 | codepublishing.com | 2026-11-29 |
| PO/RM Professional Office/Residential Multifamily | Not allowed | Land uses which are not listed as permitted or conditional uses are prohibited unless authorized Table 6.01 drive-through restaurant row: this column is blank in every reading (the blank run between GC and the HDC columns), and 18.06.040(B) prohibits unlisted uses. Restaurants without a drive-through are conditional here. | 18.06.040(B), Table 6.01 | codepublishing.com | 2026-11-29 |
| PUD Planned Unit Development | Not confirmed | Not read closely enough to state a rule. | tconline.co.thurston.wa.us | 2026-11-29 | |
| R1/5 Residential - 1 Unit Per 5 Acres | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| R-4 Residential - 4 Units per Acre | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| R-4-8 Residential 4-8 Units per Acre (written R 4-8 in the code) | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| R-4CB Residential - 4 Units per Acre (CB) | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| R-6-12 Residential 6-12 Units per Acre (written R 6-12 in the code) | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| RLI Residential Low Impact | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| RM-18 Residential Multifamily - 18 Units per Acre | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| RM-24 Residential Multifamily - 24 Units per Acre | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| RMH Residential Multifamily - High Rise | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| RMU Residential Mixed Use | Not allowed | Drive-in and drive-through businesses and uses. Listed as prohibited in RMU; Table 4.01 allows only drive-in businesses legally established before June 19, 1995 (18.04.060(J)). Restaurants without drive-through are permitted. | 18.04.040(B)(3)(f) | codepublishing.com | 2026-11-29 |
| UR Urban Residential | Not allowed | Drive-In and Drive-Through Businesses, Existing No new drive-through restaurant is listed for this district; Table 4.01 has no restaurant-with-drive-through entry here. | 18.04.040 Table 4.01 | codepublishing.com | 2026-11-29 |
| UV Urban Village | By right | Banks, restaurants, pharmacies, and other businesses that primarily cater to pedestrians or walk-in customers are permitted to have a single drive-through lane. Table 5.01 'Restaurants' row is P only in Urban Village, citing 18.05.060(A) and 18.05A.095. Limited to one drive-through lane, and the business must mainly serve walk-in customers: 18.05.040(B)(1) bars auto-oriented uses that primarily cater to customers in vehicles, so a drive-thru-only kiosk would not qualify. Lane access only through a common parking lot, must not impede pedestrian access to the entry, and not on streets abutting a village green or park. | 18.05.040 Table 5.01; 18.05.060(A)(1)-(2); 18.05.040(B)(1) | codepublishing.com | 2026-11-29 |
| UW Urban Waterfront | Not allowed | Drive-through and drive-in uses are prohibited as a primary or accessory use. Drive-through banks are conditional under the same subsection. Drive-in or drive-through restaurants existing before January 1, 1994 are conforming; no new ones. | 18.06.060(F)(2) | codepublishing.com | 2026-11-29 |
| UWH Urban Waterfront-Housing (written UW-H in the code) | Not allowed | Land uses which are not listed as permitted or conditional uses are prohibited unless authorized Table 6.01 drive-through restaurant row: this column is blank in every reading (the blank run between GC and the HDC columns), and 18.06.040(B) prohibits unlisted uses. Restaurants without a drive-through are permitted. | 18.06.040(B), Table 6.01 | codepublishing.com | 2026-11-29 |
"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.
Official zoning map layer
To find the district for a parcel, query the jurisdiction's own GIS zoning layer: https://tconline.co.thurston.wa.us/server/rest/services/ThurstonExt/Thurston_Zoning/MapServer/1 (district field: ZoneCode)
Thurston County combined zoning layer; it includes City of Olympia zoning per its metadata. Filter Jurisdiction = 'OLYMPIA' (31 distinct codes returned). Layer spellings differ from the code: CS-H (CSH), UWH (UW-H), LI (LI/C), R 1/5, R-4-8, R-6-12. MR 7-13, RMH, NC, COSC and CMR did not appear in the Olympia query; metadata says last updated 11/30/2021, so confirm current zoning with the city. Unsettled: HDC-1 and HDC-4 (Table 6.01 drive-through row cannot be aligned between HDC-1/2/3 and HDC-2/3/4 from flattened text, and no 18.06.060 text names them); CMR (no use-table column); CAP and PUD (not in use tables). District codes saved here use the map layer's spelling where it differs (CS-H, UWH, LI, R-4-8, R-6-12).
Sources
- https://codepublishing.com/WA/Olympia/html/Olympia18/Olympia1806.html
- https://tconline.co.thurston.wa.us/server/rest/services/ThurstonExt/Thurston_Zoning/MapServer/1
- https://codepublishing.com/WA/Olympia/html/Olympia18/Olympia1805.html
- https://codepublishing.com/WA/Olympia/html/Olympia18/Olympia1808.html
- https://codepublishing.com/WA/Olympia/html/Olympia18/Olympia1804.html
How to confirm before you buy
- Look up the parcel on the official zoning map to get its district and any overlay.
- Open the code section linked in the table and read the use table and the drive-thru standards.
- Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.
Why this library exists
I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.
If you have a site that fits a drive-thru, or you want to learn how these deals are put together, join the free Reverse Deal Finder community on Skool, see cap rates and land prices by brand, or call 1-760-392-1525. Brokers welcome: I pay commissions.
