Rural Vacant LandZoning Library
Zoning Library › Texas › Weatherford, TX

Weatherford, TX zoning: where a drive-thru restaurant is allowed

Parker County · 16 districts on file · last read 2026-11-29 · data.json

Is a drive-thru allowed in Weatherford, TX?

A drive-thru restaurant is allowed by right (no conditional use permit, special exception or rezoning) in these zoning districts: C1, C2, C3, I.

It is not allowed in 10 districts: AG, CBD, CN, MH, R1, R2, R3, RE, SF 7.5, SF 8.5.

2 districts are not confirmed yet.

Drive-thru rules in plain words

Drive-through restaurants are allowed by right in the C1, C2, C3 and Industrial districts, subject to the drive-thru design standards in Sec. 12-4-105(E). CBD and CN permit only restaurants with no drive-thru service, and residential and agricultural districts allow no restaurants. PD and RL cannot be settled from the code alone.

Code facts

Jurisdiction
City of Weatherford, Texas
Zoning code
City of Weatherford Title XII. Zoning Ordinance
Code last amended
Cover page reads 'Adopted December 16, 2025'. Later amendments not checked.
Restaurant parking
Table 6 in Sec. 12-4-105(D): 1 space per 200 (1:200) for eating/drinking establishments. A drive-thru restaurant also needs one extra waiting space per lane, on top of required parking.
Drive-thru stacking
Sec. 12-4-105(E): stacking lanes at least 9 ft wide. Restaurants need 198 ft per lane, with at least 154 ft behind the order board. Other drive-thru uses need 110 ft, auto wash or lube 44 ft, truck uses 325 ft.
Signs
Directional signs and pavement markings must show vehicle flow through the drive-thru (Sec. 12-4-105(E.5)).
Official code
weatherfordtx.gov

Approvals and how long they take

ApprovalWho decidesStepsTypical timeFeeSection
Conditional use permitCity Council, after a Planning and Zoning Commission hearing and recommendationPlanning Director recommendation; P&Z public hearing; City Council public hearing and decision by ordinance; hearing sign posted at least 10 days before.Sec. 12-2-104 source

District standards

DistrictNameMinimum lotSetbacksMax heightMax coverageRestaurantRetailGas stationCar washGrocerySection
C1Commercial Districtfront 25, side 5, street side 20, rear 10 ft45 ftBy rightBy rightConditionalConditionalNot confirmedSec. 12-3-302 source
C2Commercial/Interstate Districtfront 25, side 10, street side 20, rear 10 ft45 ftBy rightBy rightConditionalConditionalNot confirmedSec. 12-3-303 source
C3Commercial/Heavy District11,250 sq ft; 75 ft wide; 150 ft deepfront 25, side 5, street side 20, rear 20 ft45 ftBy rightBy rightConditionalConditionalNot confirmedSec. 12-3-304 source
CBDCentral Business District35 ftNot allowedBy rightNot allowedNot allowedNot confirmedSec. 12-3-300 source
CNCentral Neighborhood5,000 sq ft; 50 ft wide; 100 ft deepfront 15, side 5, street side 15, rear 15 ft35 ft80%Not allowedBy rightNot allowedNot allowedNot confirmedSec. 12-3-301 source
IIndustrial Districtfront 50, side 25, street side 25, rear 25 ftBy rightNot confirmedConditionalBy rightNot confirmedSec. 12-3-305 source

Overlays to watch

Second check against the source text: 2026-11-29 (Adoption date confirmed (cover: December 16, 2025). All by_right quotes and section numbers confirmed in the code; C1 really prints 'dine-in or thru service' (likely a typo, so medium). 12-4-105(E) numbers confirmed. CBD and CN moved from unclear to prohibited (medium; the code has no explicit unlisted-use ban). RL kept unclear. Overlays moved to profile. Planning office contact not found in the code. Text was read through WebFetch (direct downloads blocked), which paraphrases, so quotes were checked against two separate reads.).

Drive-thru restaurant rule by zoning district

DistrictDrive-thru restaurantWhat the code saysSectionSourceRead on
AG
Agricultural District
Not allowedno building or premises shall be used, configured, erected, or altered except in conformity with the following use
No eating establishment or restaurant row in the permitted, special or conditional tables.
Sec. 12-3-100weatherfordtx.gov2026-11-29
C1
Commercial District (General Commercial)
By rightEating Establishment/ Restaurant – with dine-in or thru service
Permitted-uses table, no conditional row for restaurants. The code itself says 'dine-in' (read twice), probably a typo for drive-in, so the drive-thru reading is an inference. Drive-thru standards of Sec. 12-4-105(E) apply.
Sec. 12-3-302weatherfordtx.gov2026-11-29
C2
Commercial/Interstate District
By rightEating Establishment/ Restaurant – with drive-in or thru service
Permitted-uses table. Sec. 12-4-105(E) drive-thru standards apply. Commercial Corridor Interstate overlay design standards may also apply along IH-20.
Sec. 12-3-303weatherfordtx.gov2026-11-29
C3
Commercial/Heavy District
By rightEating Establishment/ Restaurant – with drive-in or thru service
Permitted-uses table. Sec. 12-4-105(E) standards apply.
Sec. 12-3-304weatherfordtx.gov2026-11-29
CBD
Central Business District
Not allowedEating Establishment/Restaurant – with no drive-thru service
Only the no-drive-thru restaurant is permitted. No drive-thru restaurant row in the conditional table (16 conditional uses read). The code has no express 'unlisted uses are prohibited' clause, but each district bars use except in conformity with its use list, and the table names the no-drive-thru version specifically. Planning Director rules on ambiguities (Sec. 12-1-100(D)(4)).
Sec. 12-3-300weatherfordtx.gov2026-11-29
CN
Central Neighborhood
Not allowedEating Establishment/ Restaurant – with no drive-thru service
Only the no-drive-thru restaurant is permitted. No drive-thru restaurant row in the special or conditional tables. Same reasoning as CBD.
Sec. 12-3-301weatherfordtx.gov2026-11-29
I
Industrial District
By rightEating Establishment/ Restaurant–with Drive-In or Thru Service
Permitted-uses table. Sec. 12-4-105(E) standards apply.
Sec. 12-3-305weatherfordtx.gov2026-11-29
MH
Manufactured Home Park
Not allowedIn the MH district, no building or premises shall be used, configured, erected, or altered except in conformity
Not on the map layer. No restaurant row; the only conditional use is private utility facilities or electrical substation.
Sec. 12-3-207weatherfordtx.gov2026-11-29
PD
Planned Development District
Not confirmedNot read closely enough to state a rule.weatherfordtx.gov2026-11-29
R1
One-Family Residential District
Not allowedno building or premises shall be used, configured, erected, or altered except in conformity with the following use
No restaurant row in any use table.
Sec. 12-3-203weatherfordtx.gov2026-11-29
R2
Two-Family Residential District
Not allowedIn the R2 district, no building or premises shall be used, configured, erected, or altered except in conformity
No restaurant row in any use table.
Sec. 12-3-204weatherfordtx.gov2026-11-29
R3
Multi-Family Residential District
Not allowedIn the R3 district, no building or premises shall be used, configured, erected, or altered except in conformity
No restaurant row. Conditional uses are only bed and breakfast/boarding house, private utility or substation, and telephone exchange.
Sec. 12-3-205weatherfordtx.gov2026-11-29
RE
Residential Estate District
Not allowedno building or premises shall be used, configured, erected, or altered except in conformity with the following use
No restaurant row in any use table.
Sec. 12-3-200weatherfordtx.gov2026-11-29
RL
Residential Lake Lot District
Not confirmedNot read closely enough to state a rule.weatherfordtx.gov2026-11-29
SF 7.5
Single Family 7.5
Not allowedno building or premises shall be used, configured, erected, or altered except in conformity with the following use
No restaurant row in any use table.
Sec. 12-3-202weatherfordtx.gov2026-11-29
SF 8.5
Single Family 8.5
Not allowedno building or premises shall be used, configured, erected, or altered except in conformity with the following use
No restaurant row in any use table.
Sec. 12-3-201weatherfordtx.gov2026-11-29

"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.

Official zoning map layer

To find the district for a parcel, query the jurisdiction's own GIS zoning layer: https://gis.weatherfordtx.gov/arcgis/rest/services/Public_Planning_Development/MapServer/0 (district field: Code)

Layer name Zoning, polygon, fields Code and Description. Code has 15 values (AG, C1, C2, C3, CBD, CN, I, PD, R1, R2, R3, RE, RL, SF 7.5, SF 8.5); MH is in the code but not on the layer. CBD appears with two descriptions (Central Business and Commercial Business). The Zone_ID subtype list calls C3 'C/H' (Commercial/Heavy). Overlays are not zone codes on this layer.

Sources

How to confirm before you buy

  1. Look up the parcel on the official zoning map to get its district and any overlay.
  2. Open the code section linked in the table and read the use table and the drive-thru standards.
  3. Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.

Why this library exists

I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.

If you have a site that fits a drive-thru, or you want to learn how these deals are put together, join the free Reverse Deal Finder community on Skool, see cap rates and land prices by brand, or call 1-760-392-1525. Brokers welcome: I pay commissions.