Sherman, TX zoning: where a drive-thru restaurant is allowed
Is a drive-thru allowed in Sherman, TX?
We have not confirmed any zoning district in Sherman, TX where a drive-thru restaurant is allowed by right.
19 districts are not confirmed yet.
Drive-thru rules in plain words
Sherman's use chart has no separate drive-through row: restaurants are listed only by inside/outside service, each permitted by right in three districts with no SUP path, but which three could not be read from the available copies. Drive-thru restaurants need 8 stacking spaces. In the Blalock Commercial Overlay a drive-in restaurant is permitted by right on top of the base district uses; the College Park overlay bars drive-through facilities.
Code facts
- Jurisdiction
- City of Sherman, Texas
- Zoning code
- Code of Ordinances, Chapter 14 Zoning Ordinance (adopted 12/5/2022, as amended)
- Code last amended
- Chapter 14 last amended by Ord. No. 6934 (2026-05-18) per city Ordinance Updates page; use chart amended by Ord. No. 6899 (2025-11-17)
- Restaurant parking
- 1 space per 150 sq ft of gross floor area plus 8 stacking spaces for drive-thru service (Sec. 14.04.003(e)(1)).
- Drive-thru stacking
- 8 stacking spaces for restaurant drive-thru service (Sec. 14.04.003(e)(1)); no stacking dimensions given; all vehicle maneuvering must be on site (Sec. 14.04.003(b)(2)). SUP conditions may also address on-site stacking.
- Official code
- ecode360.com
- Official zoning map
- cityofsherman.maps.arcgis.com
- Planning office
- City of Sherman Planning (Development Services) 903-892-7206 (main city line) ci.sherman.tx.us
Approvals and how long they take
| Approval | Who decides | Steps | Typical time | Fee | Section |
|---|---|---|---|---|---|
| Specific use permit (SUP) | City Council, by ordinance, after Planning and Zoning Commission recommendation | Application with owner approval and fee; P&Z approves the required site plan; P&Z public hearing and recommendation; City Council public hearing and decision (approve, approve with conditions, deny). Mailed notice to owners within 200 ft at least 10 days before hearing; applicant posts signs 14 days before first hearing. SUP only where the use chart allows one; void if use discontinued 30 days. | Not stated in code | Per city fee schedule (amount not stated) | Sec. 14.06.009 source |
| Zoning change (rezoning) | City Council after Planning and Zoning Commission recommendation | Zoning amendment procedure; not read in detail | Not read | Per fee schedule | Sec. 14.06.005 source |
| Site plan | Planning and Zoning Commission (required for SUPs and in highway overlays) | Not read in detail | Not read | Per fee schedule, nonrefundable | Sec. 14.06.004 source |
District standards
| District | Name | Restaurant | Retail | Gas station | Car wash | Grocery | Section |
|---|---|---|---|---|---|---|---|
| C-1 | Retail Business | Not confirmed | Not confirmed | By right | Not confirmed | Not confirmed | Sec. 14.02.016; Art. 14.10 source |
| C-2 | General Commercial | Not confirmed | Not confirmed | Not confirmed | Conditional | Not confirmed | Sec. 14.02.017; Art. 14.10 source |
| C-N | Neighborhood Commercial | Not confirmed | Not confirmed | Conditional | Not confirmed | Not confirmed | Sec. 14.02.014; Art. 14.10 source |
| CO | Office | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 14.02.015; Art. 14.10 source |
| M-1 | Light Manufacturing | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 14.02.018; Art. 14.10 source |
| M-1.5 | Medium Manufacturing | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 14.02.019; Art. 14.10 source |
| M-2 | Heavy Manufacturing | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 14.02.020; Art. 14.10 source |
Overlays to watch
- Blalock Commercial Overlay District (Sec. 14.03.007, Ord. 6713, 2024): Adds uses on top of the base district chart: 'Restaurant, drive-in' and restaurants (inside and/or outside service) are P; menu boards and drive-thru canopies allowed in rear or required side yard with 5 ft setback. Car washes and auto repair need SUP; bulk chemical/petroleum terminals and sexually oriented businesses prohibited. Masonry/color/architectural standards; pylon signs and billboards prohibited. source
- Central Business District Overlay (Sec. 14.03.009): Downtown, Highway and Grayson County subdistricts; restaurants permitted by right in all three; drive-throughs not addressed in its use chart. 85% masonry/glass, earth-tone colors, zero setbacks downtown. source
- College Park Overlay (Sec. 14.03.006): No use may include drive-through facilities, gas pumps or canopies; restaurants only as ancillary first-floor uses up to 3,500 sq ft. source
- U.S. 75 & 82, F.M. 1417, Sam Rayburn, F.M. 691 and S.H. 289 corridor overlays (Secs. 14.03.001-.005): Design overlays (masonry, 40 ft highway setback, landscape buffer, sign limits, P&Z site plan approval); no use restrictions on restaurants or drive-throughs. source
Second check against the source text: 2026-11-29 (Re-checked all 19 districts; none could be settled, so statuses stay unclear (first pass also unclear). Added: legend, footnotes, no SUP on restaurant rows, PD quote, overlay effects (Blalock drive-in restaurant P; College Park bars drive-throughs), SUP procedure, restaurant parking. Blocked: eCode360 article pages (client_error), eCode360 print view (robots), Wayback copy (permission denied), curl to eCode360/Zoneomics/ci.sherman.tx.us (proxy 403). Fix: open https://ecode360.com/41405040 or the city 2022 PDF pp. 163-176 visually to map the three restaurant P marks.).
Drive-thru restaurant rule by zoning district
| District | Drive-thru restaurant | What the code says | Section | Source | Read on |
|---|---|---|---|---|---|
| C-1 Retail Business | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| C-2 General Commercial | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| C-N Neighborhood Commercial | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| CO Office | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| M-1 Light Manufacturing | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| M-1.5 Medium Manufacturing | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| M-2 Heavy Manufacturing | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| MF-15 Multi-Family Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| MF-30 Multi-Family Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| MH Manufactured Housing | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| PD Planned Development | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| R-2F Duplex Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| R-4 Patio Home Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| R-5 Single-Family Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| R-6 Single-Family Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| R-12 Single-Family Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| R-A Single-Family Agricultural | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| R-E Estate Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 | |
| R-TH Townhome Residential | Not confirmed | Not read closely enough to state a rule. | zoneomics.com | 2026-11-29 |
"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.
Official zoning map layer
To find the district for a parcel, query the jurisdiction's own GIS zoning layer: https://services7.arcgis.com/iMHDvyzuG2Q2tuit/ArcGIS/rest/services/Zoning_Districts__SDE_/FeatureServer/0 (district field: ZONECLASS)
City of Sherman GIS layer; distinct ZONECLASS values re-confirmed 2026-11-29 (18): C-1, C-2, C-N, CO, M-1, M-1.5, M-2, MF-15, MF-30, MH, PD, R-12, R-2F, R-4, R-5, R-6, R-A, R-TH. R-E (Estate Residential) is in the code but not on the layer; added as code-only. Layer CO = code C-O. WHY ALL UNCLEAR: permitted uses for every district are set only by the Art. 14.10 use chart. The chart has no drive-through row; the three restaurant rows each show exactly three 'P' marks and no SUP. Every copy that could be read (Zoneomics chapter_10; city-hosted 2022 adopted Chapter 14 PDF, use chart pp. 163-176) loses blank cells, so the P marks cannot be assigned to district columns. eCode360 article pages returned client errors (print view robots-disallowed); direct downloads of eCode360, Zoneomics and ci.sherman.tx.us are blocked by this session's proxy (403), so the PDF could not be laid out locally. A reader with the eCode360 chart (https://ecode360.com/41405040) or the city PDF opened visually can settle all districts in minutes.
Sources
How to confirm before you buy
- Look up the parcel on the official zoning map to get its district and any overlay.
- Open the code section linked in the table and read the use table and the drive-thru standards.
- Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.
Why this library exists
I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.
If you have a site that fits a drive-thru, or you want to learn how these deals are put together, join the free Reverse Deal Finder community on Skool, see cap rates and land prices by brand, or call 1-760-392-1525. Brokers welcome: I pay commissions.
