Rural Vacant LandZoning Library
Zoning Library › Texas › Georgetown, TX

Georgetown, TX zoning: where a drive-thru restaurant is allowed

Williamson County · 17 districts on file · last read 2026-11-19 · data.json

Is a drive-thru allowed in Georgetown, TX?

A drive-thru restaurant is allowed by right (no conditional use permit, special exception or rezoning) in these zoning districts: BP, C-1, C-3.

It needs a conditional or special use approval in: CN, IN, MU-DT.

It is not allowed in 11 districts: AG, MF-1, MF-2, MH, OF, PF, RE, RL, RS, TF, TH.

Drive-thru rules in plain words

Drive-through restaurants are permitted by right in C-3 (General Commercial) and with limitations in C-1 (Local Commercial) and BP (Business Park, only as a secondary use, 2,500 sf max, not freestanding without an SUP). They need a City Council Special Use Permit in CN, IN and MU-DT, and are not allowed in OF, PF, AG or any residential district. All need a Site Development Plan and must meet the Chapter 9 stacking rules.

Code facts

Jurisdiction
City of Georgetown, Texas
Zoning code
Unified Development Code (UDC)
Code last amended
Latest ordinance seen: Ord. No. 2025-08 (3-11-2025, Ch. 3); Table 5.04.010 history through Ord. No. 2022-55 (7-26-2022), as shown on Zoneomics copy
Restaurant parking
1 space per 100 sf of designated seating/entertainment area plus 4 spaces (Table 9.02.030.A, Food and Beverage Establishments); no separate drive-through ratio.
Drive-thru stacking
Restaurant drive-through: 6 stacking spaces measured from the order box plus 4 from order box to pick-up window, in addition to required parking (Table 9.04.010). Each space min 10 ft x 20 ft; may not block on/off-site traffic or parking movements; Director may require raised medians separating stacking lanes (Sec. 9.04.020).
Signs
C-1/C-3 (Table 10.06.010, Sec. 10.06.030): monument signs max 6 ft high, 1 sf per linear ft of primary facade up to 48 sf per face, 1 per 500 ft frontage, 5 ft setback; low-profile pole signs max 20 sf and 10 ft; wall signs 1 sf per linear ft of primary facade. Monument or low-profile pole are the only permanent freestanding signs except on IH-35/SH-130/SH-195 frontage (IH-35 pole signs up to 225 sf, 28 ft). Multi-tenant sites need a Master Sign Plan; electronic message centers in fixed/traveling mode prohibited. Menu-board rules not found.
Official code
udc.georgetown.org
Official zoning map
gis.georgetowntexas.gov
Planning office
Georgetown Planning Department 512-930-3575 planning.georgetown.org

Approvals and how long they take

ApprovalWho decidesStepsTypical timeFeeSection
Special Use PermitCity Council (after Planning and Zoning Commission public hearing and recommendation)Application by owner/agent; Director completeness check (5 working days); staff review and report; notice (published, mailed, posted at least 15 days before hearing); P&Z public hearing and recommendation; City Council public hearing and decision. Council approves a conceptual site layout. Expires 24 months after approval unless a Site Development Plan is submitted, building permit approved or CO issued; one 6-month extension possible.3.07 source
Site Development PlanAdministrative (final action authority per Sec. 2.01.020; Director and staff review)Submit per UDC Development Manual checklist; completeness check; staff review and correction notices; final action. Must be sealed by a Texas-licensed engineer, certify stormwater compliance, and include an Electric Utility Services Availability Letter.3.09 source

District standards

DistrictNameMinimum lotSetbacksMax heightMax coverageRestaurantRetailGas stationCar washSection
BPBusiness Park5-acre minimum district sizefront 25 ft, side 10 ft, rear 10 ft (larger where abutting residential)60 ftper Sec. 11.02 (not read)By rightBy rightConditionalConditionalTable 7.02.020; Table 5.04.010 source
C-1Local Commercialfront 25 ft, side 10 ft, rear 0 ft (larger where abutting residential)35 ftper Sec. 11.02 (not read)By rightBy rightConditionalConditionalTable 7.02.020; Table 5.04.010 source
C-3General Commercialfront 25 ft, side 10 ft, rear 10 ft (larger where abutting residential)60 ftper Sec. 11.02 (not read)By rightBy rightConditionalConditionalTable 7.02.020; Table 5.04.010 source
CNNeighborhood Commercialfront 20 ft, side 5 ft, rear 0 ft (larger where abutting residential)30 ftper Sec. 11.02 (not read)ConditionalBy rightNot allowedNot allowedTable 7.02.020; Table 5.04.010 source
INIndustrialfront 25 ft, side 10 ft, rear 10 ft (larger where abutting residential)60 ftper Sec. 11.02 (not read)ConditionalNot allowedConditionalConditionalTable 7.02.020; Table 5.04.010 source
MU-DTMixed-Use Downtownfront 0 ft, side 0 ft, rear 0 ft (larger where abutting residential)40 ftper Sec. 11.02 (not read)ConditionalBy rightNot allowedNot allowedTable 7.02.020; Table 5.04.010 source
OFOfficefront 25 ft, side 10 ft, rear 10 ft (larger where abutting residential)45 ftper Sec. 11.02 (not read)Not allowedNot allowedNot allowedNot allowedTable 7.02.020; Table 5.04.010 source
PFPublic Facilityfront 25 ft, side 5 ft, rear 0 ft (larger where abutting residential)45 ftper Sec. 11.02 (not read)Not allowedNot allowedNot allowedNot allowedTable 7.02.020; Table 5.04.010 source

Overlays to watch

Second check against the source text: 2026-11-19 (Re-opened Table 5.04.010 and Sec. 5.04.020.E for all by_right/conditional districts (C-1, C-3, BP, CN, IN, MU-DT). CN SUP and BP permission confirmed by limitation text; OF dash confirmed by E.2.d (drive-thru only in BP). Table rows are run-together text with 17 entries for 18 columns; MU column read as blank in every row checked, so IN/PF/MU-DT kept at medium. Code read from Zoneomics copy, not the official codified site (udc.georgetown.org did not expose text). Retail/gas/car wash columns read from same table with the same alignment; grocery has no separate row.).

Drive-thru restaurant rule by zoning district

DistrictDrive-thru restaurantWhat the code saysSectionSourceRead on
AG
Agriculture
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
AG column (first column) is a dash for both Restaurant, General and Restaurant, Drive-through; not allowed.
Table 5.04.010zoneomics.com2026-11-19
BP
Business Park
By rightA drive-thru restaurant is permitted in the BP District, subject to the limitations in Subsections a. through c. above.
Allowed with limitations: max 2,500 sf gross floor area; must be clearly secondary to and supportive of the primary use; may not be in a building with no other uses (a freestanding restaurant needs a Special Use Permit, considered only if it benefits a planned business park). Effectively a freestanding pad drive-thru is conditional. BP district minimum size 5 acres.
5.04.020.E.2.d; Table 5.04.010 (L)zoneomics.com2026-11-19
C-1
Local Commercial
By rightAn "L" indicates that a use is permitted, provided that it meets additional standards
Shown as L (allowed with limitations, notes E, A). Restaurant subsection E sets no C-1-specific limit; Sec. 5.04.020.A caps C-1 floor-area ratio at 0.5. Stacking: 6 spaces to order box + 4 order box to pickup window, 10x20 ft each (9.04). Site Development Plan required.
Table 5.04.010 (L); 5.01.020.B; 5.04.020.Azoneomics.com2026-11-19
C-3
General Commercial
By rightA "P" indicates that a use is allowed by right.
Permitted by right. Stacking: 6 spaces to order box + 4 order box to pickup window, 10x20 ft each (9.04). Site Development Plan required.
Table 5.04.010 (P); 5.01.020.Bzoneomics.com2026-11-19
CN
Neighborhood Commercial
ConditionalA drive-thru restaurant shall require approval of a Special Use Permit.
Special Use Permit from City Council (Sec. 3.07) after P&Z hearing. Restaurant gross floor area max 2,500 sf (5.04.020.E.1.a); district FAR max 0.3 and max 7,500 sf per building (5.04.020.A). Drive-thru stacking per Table 9.04.010.
5.04.020.E.1.b; Table 5.04.010zoneomics.com2026-11-19
IN
Industrial
ConditionalAn "S" indicates that a use is allowed only if granted a Special Use Permit by the City Council
Special Use Permit from City Council (Sec. 3.07). Confidence medium: the Zoneomics text rows have 17 entries for 18 columns; reading assumes the MU column is blank, which is consistent across every row checked, but the IN/PF/MU-DT cells could not be matched to a rendered grid.
Table 5.04.010 (S); 5.01.020.Bzoneomics.com2026-11-19
MF-1
Low-Density Multifamily
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Residential district: no restaurant uses in the residential use table (5.02.010); non-residential table shows a dash in this column.
Tables 5.02.010, 5.04.010zoneomics.com2026-11-19
MF-2
High-Density Multifamily
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Residential district: no restaurant uses in the residential use table (5.02.010); non-residential table shows a dash in this column.
Tables 5.02.010, 5.04.010zoneomics.com2026-11-19
MH
Manufactured Housing
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Residential district: no restaurant uses in the residential use table (5.02.010); non-residential table shows a dash in this column.
Tables 5.02.010, 5.04.010zoneomics.com2026-11-19
MU-DT
Mixed-Use Downtown
ConditionalAn "S" indicates that a use is allowed only if granted a Special Use Permit by the City Council
Special Use Permit from City Council. Downtown Overlay standards (Sec. 4.08.070) and Historic/Courthouse View overlays may also apply (certificate of appropriateness, 40 ft height). Confidence medium: column alignment (17 entries for 18 columns) assumed MU column blank.
Table 5.04.010 (S); 5.01.020.Bzoneomics.com2026-11-19
OF
Office
Not allowedA drive-thru restaurant is permitted in the BP District, subject to the limitations in Subsections a. through c. above.
Drive-through row shows a dash in OF; the OF/BP restaurant subsection allows drive-thru only in BP. General (non-drive-thru) restaurants are L in OF: max 2,500 sf, secondary to primary use, not in a single-use building.
Table 5.04.010; 5.04.020.E.2zoneomics.com2026-11-19
PF
Public Facility
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Dash in PF column under the column reading used (MU column blank). Confidence medium for the same alignment reason as IN/MU-DT. General restaurants are L in PF.
Table 5.04.010zoneomics.com2026-11-19
RE
Residential Estate
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Residential district: no restaurant uses in the residential use table (5.02.010); non-residential table shows a dash in this column.
Tables 5.02.010, 5.04.010zoneomics.com2026-11-19
RL
Residential Low Density
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Residential district: no restaurant uses in the residential use table (5.02.010); non-residential table shows a dash in this column.
Tables 5.02.010, 5.04.010zoneomics.com2026-11-19
RS
Residential Single-Family
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Residential district: no restaurant uses in the residential use table (5.02.010); non-residential table shows a dash in this column.
Tables 5.02.010, 5.04.010zoneomics.com2026-11-19
TF
Two-Family
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Residential district: no restaurant uses in the residential use table (5.02.010); non-residential table shows a dash in this column.
Tables 5.02.010, 5.04.010zoneomics.com2026-11-19
TH
Townhouse
Not allowedRestaurant, Drive-through — — — — — — — — — S L P — L S — S
Residential district: no restaurant uses in the residential use table (5.02.010); non-residential table shows a dash in this column.
Tables 5.02.010, 5.04.010zoneomics.com2026-11-19

"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.

Official zoning map layer

To find the district for a parcel, query the jurisdiction's own GIS zoning layer: https://gis.georgetowntexas.gov/arcgis/rest/services/Planning/P_Z_WebMap/MapServer/20 (district field: ZONE)

Layer answered (MapServer layer 20 'Zoning'; ZONE = abbreviation, FULLZONE = name). Distinct query returned 17 values. Code also lists PUD and MU (not present on the layer) and overlays. Code text read from Zoneomics copy of the UDC.

Sources

How to confirm before you buy

  1. Look up the parcel on the official zoning map to get its district and any overlay.
  2. Open the code section linked in the table and read the use table and the drive-thru standards.
  3. Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.

Why this library exists

I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.

If you have a site that fits a drive-thru, or you want to learn how these deals are put together, join the free Reverse Deal Finder community on Skool, see cap rates and land prices by brand, or call 1-760-392-1525. Brokers welcome: I pay commissions.