Rural Vacant LandZoning Library
Zoning Library › Nevada › Clark County (unincorporated), NV

Clark County (unincorporated), NV zoning: where a drive-thru restaurant is allowed

40 districts on file · last read 2026-11-16 · data.json

Is a drive-thru allowed in Clark County (unincorporated), NV?

A drive-thru restaurant is allowed by right (no conditional use permit, special exception or rezoning) in these zoning districts: CC, CG, CN, CR, CU, H-1.

It needs a conditional or special use approval in: IL, IP.

It is not allowed in 10 districts: RM18, RM32, RM50, RS2, RS3.3, RS5.2, RS10, RS20, RS40, RS80.

22 districts are not confirmed yet.

Drive-thru rules in plain words

Title 30 has no separate drive-thru use; a drive-thru restaurant follows the Restaurant and Related Facilities row, which is permitted outright in CN, CG, CC, CU and CR. Any drive-thru must meet the drive-thru service standards (separate lane, stacking set by a queueing analysis) and may not sit within 200 ft of areas subject to Residential Adjacency unless the building is between them. In CP and PF (permitted with conditions) and IP and IL (special use permit) restaurants are limited to accessory, employee-serving facilities, so a stand-alone public drive-thru does not fit there.

Code facts

Jurisdiction
Clark County, Nevada (unincorporated)
Zoning code
Clark County Code Title 30, Unified Development Code
Code last amended
Latest amendment 2026-09-02, effective 2026-09-17 (cover page). Adopted 2023-08-02, effective 2024-01-01.
Restaurant parking
1 space per 150 sf (Table 30.04-2); outdoor dining 1 per 250 sf. Max 15% over minimum without a parking demand study; reductions up to 20% (30% with sustainability) under Sec. 30.04.04F, incl. 10% within 1,000 ft of a fixed transit stop.
Drive-thru stacking
No fixed count: stacking must accommodate vehicles as determined by a queueing analysis; lane separated from drive aisles and pedestrian connections and must not block parking (Sec. 30.04.05G.5, Sec. 30.04.04E.3). Stacking in drive aisles/fire lanes prohibited (Sec. 30.04.04G.6). No drive-thru lane within 200 ft of Residential Adjacency areas unless a primary building separates (Sec. 30.04.06E.2).
Signs
Sec. 30.05.02 (non-CR districts): freestanding sign area 1.25 sf per linear ft of frontage plus 0.25 sf/ft tenant panels and 0.25 sf/ft channel letters, height up to district height, 10 ft setback; monument 80 sf, 10 ft high, 1 per pad (2 on corner pad); wall signs 20% of building face plus 10% for channel letters; directional signs 2 per entrance/exit (3 per drive-thru in CR). Near residential: freestanding max 20 ft and 60 ft from Residential Adjacency areas (Sec. 30.04.06I).
Typical approval time
By-right restaurant: Administrative Design Review (Zoning Administrator, no hearing) for development under 25,000 sf, 10 working days per code. Special use permit or Design Review: public hearing before the Zoning Commission (Board in listed cases) with Town Advisory Board recommendation; notice mailed 10 days ahead to owners within 1,500 ft.
Official code
clarkcountynv.gov
Official zoning map
maps.clarkcountynv.gov
Planning office
Clark County Comprehensive Planning Department (702) 455-4314 (press 2, then 1 for zoning) clarkcountynv.gov

Approvals and how long they take

ApprovalWho decidesStepsTypical timeFeeSection
Administrative Design Review (ADR)Zoning AdministratorStaff review; no public notice or hearing. Required for initial non-single-family development under 25,000 sf; adding drive-thru windows or queuing features is listed as ADR review.10 working daysSec. 30.06.05A source
Design Review (DR)Zoning Commission (Board of County Commissioners in listed cases)Public meeting; required for initial non-single-family development of 25,000 sf or more or filed with another application. Expires in 2 years if not commenced.Sec. 30.06.05B source
Special Use Permit (UC)Zoning Commission and/or Board of County Commissioners; Town Advisory Board recommendsApplication, newspaper and mailed notice (1,500 ft, 10 days), posted sign, public hearing; criteria: harmony with Master Plan, no undue adverse effect, adequate public facilities.Sec. 30.06.05D source
Waiver of Development Standards (WS)Zoning Commission (Board in listed cases)Public hearing; used when a development standard cannot be met.Sec. 30.06.06F source

District standards

DistrictNameMinimum lotSetbacksMax heightMax coverageRestaurantRetailGas stationCar washGrocerySection
CCCommercial CoreNoneFront 10 ft; side/rear none; street side 10 ft55 ft75%By rightBy rightNot confirmedNot confirmedNot confirmedSec. 30.02.15; Table 30.03-1 source
CGCommercial GeneralNoneFront 10 ft; side/rear none; street side 10 ft50 ft60%By rightBy rightNot confirmedNot confirmedNot confirmedSec. 30.02.14; Table 30.03-1 source
CNCommercial NeighborhoodNoneFront 10 ft; side/rear none; street side 10 ft35 ft60%By rightBy rightNot confirmedNot confirmedNot confirmedSec. 30.02.12; Table 30.03-1 source
CPCommercial ProfessionalNoneFront 15 ft; side/rear none; street side 10 ft35 ft60%By rightBy rightNot confirmedNot confirmedNot confirmedSec. 30.02.13; Table 30.03-1 source
CRCommercial ResortNoneFront 10 ft; side/rear none; street side 10 ftNot listedNot listed (density limits apply)By rightBy rightNot confirmedNot confirmedNot confirmedSec. 30.02.17; Table 30.03-1 source
CUCommercial UrbanNoneFront 10 ft; side/rear none; street side 10 ft200 ftNot listedBy rightBy rightNot confirmedNot confirmedNot confirmedSec. 30.02.16; Table 30.03-1 source
IHIndustrial HeavyNot listedFront 20 ft; side/rear none; street side 20 ft75 ft80%Not allowedNot confirmedNot confirmedNot confirmedNot confirmedSec. 30.02.20; Table 30.03-1 source
ILIndustrial LightNot listedFront 20 ft; side/rear none; street side 20 ft50 ft80%ConditionalBy rightNot confirmedNot confirmedNot confirmedSec. 30.02.19; Table 30.03-1 source
IPIndustrial ParkNot listedFront 20 ft; side/rear none; street side 20 ft50 ft80%ConditionalBy rightNot confirmedNot confirmedNot confirmedSec. 30.02.18; Table 30.03-1 source

Overlays to watch

Second check against the source text: 2026-11-16 (Read the whole 2026 Title 30 PDF in 100k-character chunks via WebFetch. Restaurant row 'P C P P P P S S S C' identical in 2024 and 2026 editions; column alignment inferred because blank cells drop out, using the restaurant standard (Sec. 30.03.06D.5.i), which names exactly CP, IP, IL, AG, PF, and the matching 10-value Retail and Outdoor Dining rows. IH and OS treated as blank (prohibited, low confidence). The code never defines what happens if a C condition cannot be met. No old-to-new district conversion table in Title 30 except the H-1 to CR note. No fee schedule in Title 30.).

Drive-thru restaurant rule by zoning district

DistrictDrive-thru restaurantWhat the code saysSectionSourceRead on
C-1Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
C-2Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
C-3Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
C-PNot confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
CC
Commercial Core
By rightRestaurant and Related Facilities P C P P P P S S S C
Restaurant is P (permitted). Drive-thru: no separate drive-thru use in Table 30.03-1; any use with a drive-thru must meet Sec. 30.04.05G.5 (lane separated from drive aisles and pedestrian connections, must not block parking; stacking sized by a queueing analysis) and Sec. 30.04.06E.2 (no drive-thru lane within 200 ft of areas subject to Residential Adjacency unless a primary building separates them). Site plan goes through Administrative Design Review (under 25,000 sf, Zoning Administrator) or Design Review (25,000 sf or more, Zoning Commission). Column alignment inferred: the 10-value row matches the 10 nonresidential districts CN, CP, CG, CC, CU, CR, IP, IL, AG, PF, and the restaurant standard Sec. 30.03.06D.5.i names exactly the non-P districts (CP, IP, IL, AG, PF); same row in the 2024 and 2026 editions.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
CG
Commercial General
By rightRestaurant and Related Facilities P C P P P P S S S C
Restaurant is P (permitted). Drive-thru: no separate drive-thru use in Table 30.03-1; any use with a drive-thru must meet Sec. 30.04.05G.5 (lane separated from drive aisles and pedestrian connections, must not block parking; stacking sized by a queueing analysis) and Sec. 30.04.06E.2 (no drive-thru lane within 200 ft of areas subject to Residential Adjacency unless a primary building separates them). Site plan goes through Administrative Design Review (under 25,000 sf, Zoning Administrator) or Design Review (25,000 sf or more, Zoning Commission). Column alignment inferred: the 10-value row matches the 10 nonresidential districts CN, CP, CG, CC, CU, CR, IP, IL, AG, PF, and the restaurant standard Sec. 30.03.06D.5.i names exactly the non-P districts (CP, IP, IL, AG, PF); same row in the 2024 and 2026 editions.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
CITY
Incorporated city
Not confirmedNot read closely enough to state a rule.maps.clarkcountynv.gov2026-11-16
CN
Commercial Neighborhood
By rightRestaurant and Related Facilities P C P P P P S S S C
Restaurant is P (permitted). Drive-thru: no separate drive-thru use in Table 30.03-1; any use with a drive-thru must meet Sec. 30.04.05G.5 (lane separated from drive aisles and pedestrian connections, must not block parking; stacking sized by a queueing analysis) and Sec. 30.04.06E.2 (no drive-thru lane within 200 ft of areas subject to Residential Adjacency unless a primary building separates them). Site plan goes through Administrative Design Review (under 25,000 sf, Zoning Administrator) or Design Review (25,000 sf or more, Zoning Commission). Column alignment inferred: the 10-value row matches the 10 nonresidential districts CN, CP, CG, CC, CU, CR, IP, IL, AG, PF, and the restaurant standard Sec. 30.03.06D.5.i names exactly the non-P districts (CP, IP, IL, AG, PF); same row in the 2024 and 2026 editions.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
CP
Commercial Professional
Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
CR
Commercial Resort
By rightRestaurant and Related Facilities P C P P P P S S S C
Restaurant is P (permitted). Drive-thru: no separate drive-thru use in Table 30.03-1; any use with a drive-thru must meet Sec. 30.04.05G.5 (lane separated from drive aisles and pedestrian connections, must not block parking; stacking sized by a queueing analysis) and Sec. 30.04.06E.2 (no drive-thru lane within 200 ft of areas subject to Residential Adjacency unless a primary building separates them). Site plan goes through Administrative Design Review (under 25,000 sf, Zoning Administrator) or Design Review (25,000 sf or more, Zoning Commission). Column alignment inferred: the 10-value row matches the 10 nonresidential districts CN, CP, CG, CC, CU, CR, IP, IL, AG, PF, and the restaurant standard Sec. 30.03.06D.5.i names exactly the non-P districts (CP, IP, IL, AG, PF); same row in the 2024 and 2026 editions.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
CU
Commercial Urban
By rightRestaurant and Related Facilities P C P P P P S S S C
Restaurant is P (permitted). Drive-thru: no separate drive-thru use in Table 30.03-1; any use with a drive-thru must meet Sec. 30.04.05G.5 (lane separated from drive aisles and pedestrian connections, must not block parking; stacking sized by a queueing analysis) and Sec. 30.04.06E.2 (no drive-thru lane within 200 ft of areas subject to Residential Adjacency unless a primary building separates them). Site plan goes through Administrative Design Review (under 25,000 sf, Zoning Administrator) or Design Review (25,000 sf or more, Zoning Commission). Column alignment inferred: the 10-value row matches the 10 nonresidential districts CN, CP, CG, CC, CU, CR, IP, IL, AG, PF, and the restaurant standard Sec. 30.03.06D.5.i names exactly the non-P districts (CP, IP, IL, AG, PF); same row in the 2024 and 2026 editions.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
H-1
Limited Resort and Apartment (legacy)
By rightH-1 zoning has been updated to CR (Commercial Resort) on January 1, 2024 per Ord.5060.
Legacy district, converted to CR by Title 30 Sec. 30.06.05D.1.ii(a) (note citing Ord. 5060). CR status applies: restaurant P. Drive-thru: no separate drive-thru use in Table 30.03-1; any use with a drive-thru must meet Sec. 30.04.05G.5 (lane separated from drive aisles and pedestrian connections, must not block parking; stacking sized by a queueing analysis) and Sec. 30.04.06E.2 (no drive-thru lane within 200 ft of areas subject to Residential Adjacency unless a primary building separates them). Site plan goes through Administrative Design Review (under 25,000 sf, Zoning Administrator) or Design Review (25,000 sf or more, Zoning Commission).
Sec. 30.06.05D.1.ii(a)clarkcountynv.gov2026-11-16
H-2Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
IH
Industrial Heavy
Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
IL
Industrial Light
ConditionalIn the CP, IP, IL, AG, and PF districts, an establishment must be accessory and subordinate to the primary use
Restaurant is S (special use permit, Zoning Commission/Board after public hearing) and must also be accessory to the primary use, for employees of an office complex or business park, with no independent commercial appearance; a stand-alone public drive-thru restaurant would not meet this. Drive-thru: no separate drive-thru use in Table 30.03-1; any use with a drive-thru must meet Sec. 30.04.05G.5 (lane separated from drive aisles and pedestrian connections, must not block parking; stacking sized by a queueing analysis) and Sec. 30.04.06E.2 (no drive-thru lane within 200 ft of areas subject to Residential Adjacency unless a primary building separates them). Site plan goes through Administrative Design Review (under 25,000 sf, Zoning Administrator) or Design Review (25,000 sf or more, Zoning Commission). Column alignment inferred: the 10-value row matches the 10 nonresidential districts CN, CP, CG, CC, CU, CR, IP, IL, AG, PF, and the restaurant standard Sec. 30.03.06D.5.i names exactly the non-P districts (CP, IP, IL, AG, PF); same row in the 2024 and 2026 editions.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5; Sec. 30.06.05D (Special Use Permit)clarkcountynv.gov2026-11-16
IP
Industrial Park
ConditionalIn the CP, IP, IL, AG, and PF districts, an establishment must be accessory and subordinate to the primary use
Restaurant is S (special use permit, Zoning Commission/Board after public hearing) and must also be accessory to the primary use, for employees of an office complex or business park, with no independent commercial appearance; a stand-alone public drive-thru restaurant would not meet this. Drive-thru: no separate drive-thru use in Table 30.03-1; any use with a drive-thru must meet Sec. 30.04.05G.5 (lane separated from drive aisles and pedestrian connections, must not block parking; stacking sized by a queueing analysis) and Sec. 30.04.06E.2 (no drive-thru lane within 200 ft of areas subject to Residential Adjacency unless a primary building separates them). Site plan goes through Administrative Design Review (under 25,000 sf, Zoning Administrator) or Design Review (25,000 sf or more, Zoning Commission). Column alignment inferred: the 10-value row matches the 10 nonresidential districts CN, CP, CG, CC, CU, CR, IP, IL, AG, PF, and the restaurant standard Sec. 30.03.06D.5.i names exactly the non-P districts (CP, IP, IL, AG, PF); same row in the 2024 and 2026 editions.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5; Sec. 30.06.05D (Special Use Permit)clarkcountynv.gov2026-11-16
MLZNot confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
OS
Open Space
Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
P-FNot confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
PF
Public Facility
Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-1Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-1aNot confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-2Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-3Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-4Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-5Not confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-DNot confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-ENot confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
R-UNot confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16
RM18
Residential Multi-Family 18
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RM32
Residential Multi-Family 32
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RM50
Residential Multi-Family 50
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RS2
Residential Single-Family 2
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RS3.3
Residential Single-Family 3.3
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RS5.2
Residential Single-Family 5.2
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RS10
Residential Single-Family 10
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RS20
Residential Single-Family 20
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RS40
Residential Single-Family 40
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
RS80
Residential Single-Family 80
Not allowedRestaurant and Related Facilities P C P P P P S S S C
Residential district; the restaurant row has only 10 values, all falling in the nonresidential columns. Blank = prohibited per table key.
Sec. 30.03.02 Table 30.03-1; Sec. 30.03.06D.5clarkcountynv.gov2026-11-16
U-VNot confirmedNot read closely enough to state a rule.clarkcountynv.gov2026-11-16

"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.

Official zoning map layer

To find the district for a parcel, query the jurisdiction's own GIS zoning layer: https://maps.clarkcountynv.gov/arcgis/rest/services/GISMO/Zoning/MapServer/10 (district field: ZNCLASS)

40 distinct ZNCLASS values: current Title 30 districts plus legacy pre-2024 codes and CITY. Table 30.03-1 loses blank cells in text extraction; restaurant column alignment was inferred from the use-specific standard naming CP, IP, IL, AG, PF (see verified notes), so commercial statuses are medium and IH/OS low. Legacy codes other than H-1 (converted to CR per Sec. 30.06.05D note citing Ord. 5060) are unclear: Title 30 has no conversion table. CITY = incorporated city, outside county zoning.

Sources

How to confirm before you buy

  1. Look up the parcel on the official zoning map to get its district and any overlay.
  2. Open the code section linked in the table and read the use table and the drive-thru standards.
  3. Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.

Why this library exists

I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.

If you have a site that fits a drive-thru, or you want to learn how these deals are put together, join the free Reverse Deal Finder community on Skool, see cap rates and land prices by brand, or call 1-760-392-1525. Brokers welcome: I pay commissions.