Rural Vacant LandZoning Library
Zoning Library › North Carolina › Morehead City, NC

Morehead City, NC zoning: where a drive-thru restaurant is allowed

Carteret County · 21 districts on file · last read 2026-11-26 · data.json

Is a drive-thru allowed in Morehead City, NC?

A drive-thru restaurant is allowed by right (no conditional use permit, special exception or rezoning) in these zoning districts: CH.

It is not allowed in 20 districts: CD, CM, CN, DB, FP, I, IC, MA, O&P, PD, PM, R-5, R-5S, R-7, R-10, R-15, R-15M, R-15SM, R-20, RMF.

Drive-thru rules in plain words

The UDO lists 'Restaurant, drive-in' (food or drinks consumed in cars, on or off the premises) as its own use. It is allowed only in the CH Highway Commercial district, by right with a zoning permit. No district allows it by special use permit, so it is prohibited everywhere else. A plain 'Restaurant' is limited to on-premises consumption: it needs a special use permit in O&P, is allowed in PDs of 10+ acres, and is allowed in CH and several other commercial or industrial columns that could not be aligned.

Code facts

Jurisdiction
City of Morehead City (Town of Morehead City), Carteret County, North Carolina
Zoning code
Morehead City Unified Development Ordinance (UDO)
Code last amended
Copy read is Supp. No. 19, captured 2023-11-21. The whole UDO was amended by Ord. 2021-O-14 (June 8, 2021); it was first effective June 12, 2001. A rewrite (Advance Morehead City) was still in drafting per the project site.
Restaurant parking
20-3.3(J): 1 space per 4 seats or 1 per 100 sq ft of gross floor area, whichever is less. 20-3.3(K) (drive-in): the same, plus at least 15 spaces for drive-in service. Some downtown lots are exempt by location (20-1.2).
Drive-thru stacking
No stacking or queuing-lane standard in the UDO. 20-3.3(K) requires at least 15 extra parking spaces for drive-in service. The city's Code Diagnosis report recommends adding drive-through standards.
Signs
Table 19-9.2: drive-through menu board up to 35 sq ft per face, 1 per drive-through, 8 ft maximum height, within 10 ft of the drive-through lane; internal illumination allowed (19-3.3). A menu board mounted as a wall sign counts toward total wall-sign area (19-9.3).
Typical approval time
The UDO sets no review deadline for zoning permits. Permits expire if work has not substantially begun within 1 year (4-13.1). Special use permits need a Board of Adjustment quasi-judicial hearing. On text or map changes, the Planning Board has 30 days to act (3-4.4).
Official code
advancemoreheadcity.com
Official zoning map
advancemoreheadcity.com
Planning office
Morehead City Planning and Development (Planning & Inspections, Zoning Division), 1100 Bridges St 252-726-6848 ext. 125 moreheadcitync.gov

Approvals and how long they take

ApprovalWho decidesStepsTypical timeFeeSection
Zoning permit (P uses)Land Use Administrator (planning staff)Apply to the Administrator. The Administrator checks the use against the Table of Permissible Uses and the development standards (setbacks, coverage, height, parking, landscaping), and must deny an incomplete or noncompliant application. Building permits follow.No deadline stated; expires after 1 year if work has not substantially begun4-1.1, 4-6.1, 4-6.2, 4-13.1, 11-2 source
Special use permit (S uses)Board of Adjustment (5 members), quasi-judicialFile through the Administrator, who prepares a staff report. Evidentiary hearing; the applicant carries the burden of proof on 11 criteria (4-8.3). The Board may attach conditions; a majority of members is needed. Tracts over 1 acre need an owner acknowledgment before recording.Not stated; expires if work has not substantially begun within 1 year3-5, 3-6, 4-8, 4-9, 4-10, 4-13, 4-14.2 source
Rezoning / conditional zoningCity Council (legislative), after a Planning Board recommendationThe Planning Board reviews and recommends (a change counts as approved if the Board does not act within 30 days). The Council then holds a legislative hearing under Article 24.Planning Board: 30 days3-4.2, 3-4.4, 3-12, Art. 10, Art. 24 source

District standards

DistrictNameRestaurantRetailGas stationCar washSection
CHHighway Commercial (sit-down and drive-in restaurants both permitted; service stations under Article 14 standards)By rightBy rightBy rightBy right9-12.6; 11-1 source
O&POffice and Professional (sit-down restaurant by special use permit from the Board of Adjustment; drive-in not allowed)Conditional9-14.2; 11-1 source
PDPlanned Development (sit-down restaurant only in PDs of 10+ acres, capped at 10% of built residential floor space; drive-in not allowed)Not confirmed9-15; 11-1 footnote a source

Second check against the source text: 2026-11-26 (In both copies (city-hosted UDO PDF and Zoneomics) the 'Restaurant, drive-in' row has a single P, and the city's CH use sheets place it in CH. Non-CH districts are medium because blank cells are lost in the text copies. The Restaurant row's six P columns (besides O&P=S and PD=P-a) could not be aligned beyond CH. Amendments after Supp. 19 (Nov 2023) were not checked. Shell downloads were blocked by the proxy, so the PDF could not be parsed with positions.).

Drive-thru restaurant rule by zoning district

DistrictDrive-thru restaurantWhat the code saysSectionSourceRead on
CD
Downtown commercial (mixed shops and housing)
Not allowedRestaurant, drive-in Yes P
The drive-in row's only entry is in CH. The Restaurant row's six P entries fall somewhere among MA, CD, CM, DB, CN, CH, I, PM, FP and IC; which ones besides CH could not be aligned.
UDO 11-1; 9-12.2advancemoreheadcity.com2026-11-26
CH
Highway Commercial
By rightRestaurant, drive-in Yes P
Allowed with a zoning permit from the Land Use Administrator. Parking: 1 space per 4 seats or per 100 sq ft of floor area, whichever is less, plus at least 15 spaces for drive-in service. The menu board may be up to 35 sq ft per face, 1 per drive-through, 8 ft tall, within 10 ft of the lane. No separate stacking standard. CH dimensional rules apply, and stricter standards apply next to residential districts.
UDO 11-1 Table of Permissible Uses; 11-2; 2-2.231; 20-3.3(K); 9-12.6moreheadcitync.gov2026-11-26
CM
Marina commercial (waterfront)
Not allowedRestaurant, drive-in Yes P
The drive-in row's only entry is in CH. Sit-down restaurant status was not aligned.
UDO 11-1; 9-12.3advancemoreheadcity.com2026-11-26
CN
Neighborhood commercial
Not allowedRestaurant, drive-in Yes P
The drive-in row's only entry is in CH. Sit-down restaurant status was not aligned.
UDO 11-1; 9-12.5advancemoreheadcity.com2026-11-26
DB
Central business (downtown)
Not allowedRestaurant, drive-in Yes P
The drive-in row's only entry is in CH. Sit-down restaurant status was not aligned. Some downtown lots are exempt from off-street parking (20-1.2).
UDO 11-1; 9-12.4advancemoreheadcity.com2026-11-26
FP
Floodplain
Not allowedRestaurant, drive-in Yes P
The drive-in row has only one P (CH) and no S entries anywhere, so even a special use permit is not available here.
UDO 11-1; 9-16.1advancemoreheadcity.com2026-11-26
I
Industrial
Not allowedRestaurant, drive-in Yes P
The drive-in row's only entry is in CH. Sit-down restaurant status was not aligned.
UDO 11-1; 9-13.2advancemoreheadcity.com2026-11-26
IC
Institutional Campus
Not allowedRestaurant, drive-in Yes P
The drive-in row's only entry is in CH. The district is for noncommercial campus uses on tracts of 10+ acres.
UDO 11-1; 9-14.4advancemoreheadcity.com2026-11-26
MA
Medical Arts
Not allowedRestaurant, drive-in Yes P
The drive-in row's only entry is in CH. Whether a sit-down restaurant is allowed in MA could not be aligned.
UDO 11-1; 9-14.3advancemoreheadcity.com2026-11-26
O&P
Office and Professional
Not allowedRestaurant, drive-in Yes P
A drive-in restaurant has no entry here, since its only P is in CH. A sit-down restaurant needs a Board of Adjustment special use permit: the first entry in the Restaurant row is S, and a city Board of Adjustment staff report (Dec 7, 2022) confirms it.
UDO 11-1; 9-14.2advancemoreheadcity.com2026-11-26
PD
Planned Development
Not alloweda - Only permitted in PDs with ten or more acres/limited in area to 10% of built residential floor space
A drive-in restaurant has no entry here. A sit-down restaurant (on-premises consumption) is P only in PDs of 10+ acres, capped at 10% of built residential floor space. A conditional rezoning (Article 10) would be the only other route; it was not reviewed.
UDO 11-1 (footnote a); 9-15advancemoreheadcity.com2026-11-26
PM
Port (maritime/port operations)
Not allowedRestaurant, drive-in Yes P
The drive-in row's only entry is in CH.
UDO 11-1; 9-13.3advancemoreheadcity.com2026-11-26
R-5
Residential, 5,000 sq ft lots
Not allowedRestaurant, drive-in Yes P
Neither restaurant row has an entry in any residential column: the first restaurant entry falls in O&P, which comes after all residential columns.
UDO 11-1 Table of Permissible Uses; 9-11.2advancemoreheadcity.com2026-11-26
R-5S
Residential, 5,000 sq ft lots, single-family only
Not allowedRestaurant, drive-in Yes P
No restaurant entry in residential columns.
UDO 11-1; 9-11.3advancemoreheadcity.com2026-11-26
R-7
Residential, 7,000 sq ft lots
Not allowedRestaurant, drive-in Yes P
No restaurant entry in residential columns.
UDO 11-1; 9-11.4advancemoreheadcity.com2026-11-26
R-10
Residential, 10,000 sq ft lots
Not allowedRestaurant, drive-in Yes P
No restaurant entry in residential columns.
UDO 11-1; 9-11.5advancemoreheadcity.com2026-11-26
R-15
Residential, 15,000 sq ft lots
Not allowedRestaurant, drive-in Yes P
No restaurant entry in residential columns.
UDO 11-1; 9-11.6advancemoreheadcity.com2026-11-26
R-15M
Residential, 15,000 sq ft lots, single-family and manufactured homes
Not allowedRestaurant, drive-in Yes P
No restaurant entry in residential columns.
UDO 11-1; 9-11.7advancemoreheadcity.com2026-11-26
R-15SM
Residential, 15,000 sq ft lots, single-family and single-family manufactured homes
Not allowedRestaurant, drive-in Yes P
No restaurant entry in residential columns.
UDO 11-1; 9-11.8advancemoreheadcity.com2026-11-26
R-20
Residential, 20,000 sq ft lots
Not allowedRestaurant, drive-in Yes P
No restaurant entry in residential columns.
UDO 11-1; 9-11.9advancemoreheadcity.com2026-11-26
RMF
Residential multifamily
Not allowedRestaurant, drive-in Yes P
No restaurant entry in residential columns.
UDO 11-1; 9-11.10advancemoreheadcity.com2026-11-26

"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.

Zoning map

No public GIS zoning layer found. No town zoning service found. Carteret County's ArcGIS 'Layers' folder (72 services) has Emerald_Isle_Zoning and Newport_Zoning but nothing for Morehead City. The county Layers/Zoning/MapServer/0 layer answers with f=json (fields: Zone, Zone_Description). Its zone values are county codes (B1, B1A, B2, B3, IW, LIW, MC, OP, PI, R5W, R10, R15, R15M CU, R20, RB, plus CU/CZ variants) and do not match the town's districts, so it was not used. The only town map found is a PDF listed on the city's UDO-rewrite site; I did not open it. How the use table was settled: the Zoneomics copy and the city-hosted UDO PDF (a print of Supp. No. 19, captured 2023-11-21) both lose blank cells in the use table. In both, the 'Restaurant, drive-in' row has exactly one entry, a P. The city's own Highway Commercial (CH) district use sheet (agenda item 1166) and its CH-CZ sheet (agenda item 4681) list both 'Restaurant' and 'Restaurant, Drive-In' under Permitted Uses. That single P is therefore the CH column, and every other column is blank. This rests on extracted text, not a positioned table, so non-CH districts are marked medium. Amendments made after Supp. 19 (Nov 2023) were not checked.

Sources

How to confirm before you buy

  1. Look up the parcel on the official zoning map to get its district and any overlay.
  2. Open the code section linked in the table and read the use table and the drive-thru standards.
  3. Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.

Why this library exists

I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.

If you have a site that fits a drive-thru, or you want to learn how these deals are put together, join the free Reverse Deal Finder community on Skool, see cap rates and land prices by brand, or call 1-760-392-1525. Brokers welcome: I pay commissions.