Bowling Green, KY zoning: where a drive-thru restaurant is allowed
Is a drive-thru allowed in Bowling Green, KY?
We have not confirmed any zoning district in Bowling Green, KY where a drive-thru restaurant is allowed by right.
It is not allowed in 10 districts: MHP, R-E, RM-2, RM-3, RM-4, RR, RS-1A, RS-1B, RS-1C, RS-1D.
36 districts are not confirmed yet.
Drive-thru rules in plain words
The Sec. 5.1 Use Table has separate rows for Eating Establishment with and without drive-through. Legend: P permitted, C conditional, * specific use standards apply. The with-drive-through row shows four P* marks (no C), meaning permitted with standards in four of the 17 district columns, but the marks could not be tied to district columns. Drive-throughs must be 100 ft from residential uses (Sec. 5.2.4.A.5.b); some historic and urban growth overlay areas prohibit them.
Code facts
- Jurisdiction
- Joint Zoning Ordinance of Warren County, Kentucky and the incorporated cities (including Bowling Green)
- Zoning code
- Zoning Ordinance (joint, administered by the City-County Planning Commission of Warren County)
- Code last amended
- Text read is Article 4 and Article 5 dated April 2021 (from the PDF file names). The regulations page also links Article 5 on Google Drive, which is not readable by the tools used, so later amendments (possibly a 2026 revision) are unverified. Confidence capped at medium.
- Restaurant parking
- Sec. 4.6.8.E.1: table service and counter service 1 space per 100 sq ft; fast food 1 space per 200 sq ft.
- Drive-thru stacking
- Sec. 4.6.8.E.12: restaurant with menu board 5 stacking spaces per lane; pickup window only 3; other drive-through 3; each space at least 8 by 20 ft.
- Signs
- Drive-through menu boards limited to 36 sq ft, preview boards 6 sq ft, drive-in boards 6 sq ft each (Sec. 5.2.4.A.5). Electronic message signs prohibited in local historic districts (Sec. 4.6.8.F.5.e).
- Typical approval time
- Applications filed at least 28 days before hearing; legislative body must act on a rezoning within 90 days of the Planning Commission recommendation (Secs. 3.1.2, 3.11.7).
- Official code
- warrenpc.org
- Official zoning map
- warrenpc.org
- Planning office
- City-County Planning Commission of Warren County 270.842.1953 warrenpc.org
Approvals and how long they take
| Approval | Who decides | Steps | Typical time | Fee | Section |
|---|---|---|---|---|---|
| Conditional use permit | Board of Adjustments | Application with site plan and boundary survey; public hearing with notice; majority vote of members present; board may attach conditions. | Filing at least 28 days before hearing | Nonrefundable fee set by the Planning Commission; amount not read | Sec. 3.9; Sec. 3.1 source |
| Zoning map amendment (rezoning), with general development plan conditions | Planning Commission recommends; the legislative body decides | Mandatory pre-application conference; application with survey and possibly general development plan; hearing; legislative body acts. | Legislative body acts within 90 days of recommendation | Nonrefundable fee; amount not read | Sec. 3.11; Sec. 3.12.3 source |
| Site development plan | Planning Commission staff after CDR committee review | Pre-CDR conference; submission; CDR recommendation; 5-day public review. Required for 1 acre or more disturbed, new public improvements, a traffic impact study, UG overlay or PUD. | Submit within 2 years of a map amendment | not read | Sec. 3.12.5 to 3.12.7 source |
District standards
| District | Name | Minimum lot | Setbacks | Max height | Max coverage | Restaurant | Retail | Gas station | Car wash | Grocery | Section |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AG | Agriculture | 5 acres | front 25 ft, side 10 ft, rear 25 ft | not stated | 25% | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.3 source |
| CB | Central Business | none stated (0) | 0; 25 ft from single-family | none stated | 100% | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.6 source |
| F | General Flood | not stated | not stated | not stated | not stated | Not allowed | Not allowed | Not allowed | Not allowed | Not allowed | Sec. 4.8.2 source |
| GB | General Business | 5,000 sq ft (public sewer) | front 25 ft, side 5 ft, rear 5 ft; 40 ft from single-family | 42 ft | 80% | Not confirmed | Not confirmed | unclear (max 4 pumps / 8 vehicles) | Not confirmed | Not confirmed | Sec. 4.6; Sec. 5.2.4.I.5.a source |
| HB | Highway Business | 5,000 sq ft (public sewer) | front 25 ft, side 5 ft, rear 5 ft; 40 ft from single-family | none stated | 90% | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.6 source |
| HI | Heavy Industrial | 5,000 sq ft sewer / 1 acre septic | front 25 ft, side 5 ft, rear 5 ft; 50 ft side/rear next to residential | 100 ft | 90% | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.7.3 source |
| LI | Light Industrial | 5,000 sq ft sewer / 1 acre septic | front 25 ft, side 5 ft, rear 5 ft; 50 ft side/rear next to residential | 100 ft | 90% | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.7.3 source |
| MHP | Mobile Home Park | not read | not read | not read | not read | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.4.4 source |
| NB | Neighborhood Business | 5,000 sq ft (public sewer) | front 25 ft, side 10 ft, rear 25 ft; 25 ft from single-family | 42 ft | 70% | Not confirmed | Not confirmed | unclear (max 4 pumps / 8 vehicles) | Not confirmed | Not confirmed | Sec. 4.6; Sec. 5.2.4.I.5.a source |
| OP-C | Office/Professional Commercial | 5,000 sq ft (public sewer) | front 25 ft, side 5 ft, rear 5 ft; 40 ft from single-family | none stated | 80% | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.6 source |
| OP-R | Office/Professional Residential | 5,000 sq ft (public sewer) | front 25 ft, side 10 ft, rear 25 ft; 25 ft from single-family | 42 ft | 50% | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.6 source |
| P | Public | 5,000 sq ft (public sewer) | front 25 ft, side 0 ft, rear 0 ft; 25 ft from single-family | none stated | 90% | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.6 source |
| PUD | Planned Unit Development | 1 acre | per approved plan | per approved plan | per approved plan | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.8.1 source |
| R-E | Residential Estate | 1 acre | front 25 ft, side 10 ft, rear 10 ft | 42 ft | 30% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.4.2 source |
| RM-2 | Two-Family Residential | 10,000 sq ft | front 25 ft, side 7.5 ft, rear 10 ft | 42 ft | 75% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.5.1 source |
| RM-3 | Townhouse and Multi-Family | 8,000 sq ft + 2,000 sq ft per additional unit | front 25 ft, side 7.5 ft, rear 10 ft | 42 ft | 80% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.5.2 source |
| RM-4 | Multi-family | 5,000 sq ft | front 25 ft, side 5 ft, rear 10 ft | 6 stories above grade | 85% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.5.3 source |
| RR | Rural Residential | 2 acres | front 25 ft, side 25 ft, rear 25 ft | 42 ft | 30% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.4.1 source |
| RS-1A | RS-1A Single Family | 12,000 sq ft | front 25 ft, side 10 ft, rear 10 ft | 42 ft | 50% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.4.3 source |
| RS-1B | RS-1B Single Family | 10,000 sq ft | front 25 ft, side 7.5 ft, rear 10 ft | 42 ft | 60% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.4.3 source |
| RS-1C | RS-1C Single Family | 8,000 sq ft | front 25 ft, side 7.5 ft, rear 10 ft | 42 ft | 70% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.4.3 source |
| RS-1D | RS-1D Single Family | 5,000 sq ft | front 25 ft, side 5 ft, rear 10 ft | 42 ft | 75% | Not allowed | Not confirmed | Not confirmed | Not confirmed | Not confirmed | Sec. 4.4.3 source |
Overlays to watch
- General rule: Where overlay and base district differ, the more restrictive standard applies (Sec. 4.9.1). source
- CSOD (Conservation Subdivision Overlay): Flexible-design conservation subdivisions on 40+ acres in unincorporated areas; uses follow the underlying district; no drive-through restriction. source
- UG (Urban Growth Overlay): Focal-point areas on Cemetery Road (KY 234) and Lovers Lane (KY 880); Cemetery Road prohibits eating establishments with drive-through or drive-in (Sec. 4.9.3.D.7); Lovers Lane list does not include drive-throughs. source
- HD (Local Historic District): Prohibits eating establishments with drive-thru in the Chestnut Dodd, Upper East Main, Downtown Commercial and College Hill districts, and retail drive-thru in some (Sec. 4.9.4.D); certificate of appropriateness for signs. source
- UD (University District): Regulates residential-style development, parking, lot coverage and signs; no restaurant or drive-through restriction seen. source
- AD (Airport Overlay): Kentucky Airport Zoning Commission may add restrictions; no restaurant restriction seen. source
Second check against the source text: 2026-11-18 (Second check. Re-read Article 4 (residential, commercial, LI/HI, PUD/F, overlays, stacking, parking), Article 3 (approvals), Article 8, and a staff report for BE. Sec. 5.1 Use Table still unmappable (two reads agree on counts: 5 P and 4 P*, 17 headers, blank cells dropped), so commercial/industrial/AG stay unclear. Residential 'prohibited' downgraded to medium because residential sections defer to Sec. 5.1. Current (post-2021) Article 5 unreadable. Dimensional figures in profile.districts for residential/business rows come from the first pass garbled table and were not re-verified.).
Drive-thru restaurant rule by zoning district
| District | Drive-thru restaurant | What the code says | Section | Source | Read on |
|---|---|---|---|---|---|
| AG Agriculture | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| AG BE Agriculture with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| AG, F Split parcel: Agriculture and General Flood | Not confirmed | Not read closely enough to state a rule. | webgis.bgky.org | 2026-11-18 | |
| AG, R-E Split parcel: Agriculture and Residential Estate | Not confirmed | Not read closely enough to state a rule. | webgis.bgky.org | 2026-11-18 | |
| CB Central Business | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| CB BE Central Business with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| F General Flood | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| GB General Business | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| GB BE General Business with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| HB Highway Business | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| HB BE Highway Business with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| HI Heavy Industrial | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| HI BE Heavy Industrial with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| LI Light Industrial | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| LI BE Light Industrial with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| MHP Mobile Home Park | Not allowed | Recognize the mobile home as a form of housing for which specific provisions should be made Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.4.4 | warrenpc.org | 2026-11-18 |
| MHP BE Mobile Home Park with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| NB Neighborhood Business | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| NB BE Neighborhood Business with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| OP-C Office/Professional Commercial | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| OP-C BE Office/Professional Commercial with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| OP-R Office/Professional Residential | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| OP-R BE Office/Professional Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| P Public | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| P BE Public with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| PUD Planned Unit Development | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| PUD BE Planned Unit Development with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| PUD BE, F Split parcel: PUD with binding elements and General Flood | Not confirmed | Not read closely enough to state a rule. | webgis.bgky.org | 2026-11-18 | |
| R-E Residential Estate | Not allowed | The Residential Estate District is intended to provide opportunities for large-lot rural estates Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.4.2 | warrenpc.org | 2026-11-18 |
| R-E BE Residential Estate with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| RM-2 Two-Family Residential | Not allowed | intended to provide housing opportunities for two-family residential development Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.5.1 | warrenpc.org | 2026-11-18 |
| RM-2 BE Two-Family Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| RM-3 Townhouse and Multi-Family Residential | Not allowed | intended to provide housing opportunities for townhouse and multi-family development Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.5.2 | warrenpc.org | 2026-11-18 |
| RM-3 BE Townhouse and Multi-Family Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| RM-4 Multi-family Residential | Not allowed | intended to provide housing opportunities for townhouse and apartment development Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.5.3 | warrenpc.org | 2026-11-18 |
| RM-4 BE Multi-Family Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| RR Rural Residential | Not allowed | The Rural Residential District provides opportunities for large lot residential development Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.4.1 | warrenpc.org | 2026-11-18 |
| RR BE Rural Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| RS-1A RS-1A Single Family Residential | Not allowed | intended to provide opportunities for detached and attached single family residential development Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.4.3 | warrenpc.org | 2026-11-18 |
| RS-1A BE RS-1A Single Family Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| RS-1B RS-1B Single Family Residential | Not allowed | intended to provide opportunities for detached and attached single family residential development Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.4.3 | warrenpc.org | 2026-11-18 |
| RS-1B BE RS-1B Single Family Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| RS-1C RS-1C Single Family Residential | Not allowed | intended to provide opportunities for detached and attached single family residential development Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.4.3 | warrenpc.org | 2026-11-18 |
| RS-1C BE RS-1C Single Family Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 | |
| RS-1D RS-1D Single Family Residential | Not allowed | intended to provide opportunities for detached and attached single family residential development Article 4 residential section lists only housing types and refers uses to the Sec. 5.1 Use Table; no restaurant or eating establishment is mentioned in the residential sections. Sec. 5.1 marks could not be tied to columns (see layer note), so prohibited rests on the absence of restaurants from the district sections and on Sec. 5.1.5 (unlisted uses not allowed). The Use Table column is shared as RS-1 for RS-1A to 1D. | Sec. 4.4.3 | warrenpc.org | 2026-11-18 |
| RS-1D BE RS-1D Single Family Residential with binding elements (development plan conditions) | Not confirmed | Not read closely enough to state a rule. | warrenpc.org | 2026-11-18 |
"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.
Official zoning map layer
To find the district for a parcel, query the jurisdiction's own GIS zoning layer: https://webgis.bgky.org/server/rest/services/CCPC/CCPC_Zoning/MapServer/0 (district field: Zoning)
Countywide CCPC zoning layer (Zoning field; confirmed in first pass, not re-queried here because the shell cannot reach the host). Codes include base districts AG, RR, R-E, RS-1A to 1D, MHP, RM-2/3/4, NB, GB, CB, HB, OP-R, OP-C, P, LI, HI, PUD, F, split values ('AG, R-E', 'AG, F', 'PUD BE, F') and 21 codes with a 'BE' suffix, plus null/blank. 'BE' = binding elements (recorded development plan conditions on a rezoning); it is not defined as such in the ordinance text read, but Article 8 equates binding elements with development plan conditions and a CCPC staff report uses 'GB BE' etc. on its zoning map. ONLY the April 2021 Article 4 and Article 5 were readable; the current Article 5 linked on the regulations page (Google Drive, 1Ip3LmPRqV-A8MR6mPv2T26I2GjzPurio) is robots-blocked and the Dec 2019 PDFs return client errors, so the text may be out of date. Sec. 5.1 Use Table could not be tied to columns: the extraction drops blank cells in two reads, so commercial/industrial/AG status is unclear. Overall confidence capped at medium. Layer covers the whole county; the joint ordinance applies inside Bowling Green.
Sources
How to confirm before you buy
- Look up the parcel on the official zoning map to get its district and any overlay.
- Open the code section linked in the table and read the use table and the drive-thru standards.
- Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.
Why this library exists
I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.
If you have a site that fits a drive-thru, or you want to learn how these deals are put together, join the free Reverse Deal Finder community on Skool, see cap rates and land prices by brand, or call 1-760-392-1525. Brokers welcome: I pay commissions.