Is a drive-thru allowed in Vanderburgh County (unincorporated), IN?

A drive-thru restaurant is allowed by right (no conditional use permit, special exception or rezoning) in these zoning districts: C-1, C-2, C-4, M-1, M-2.

It is not allowed in 9 districts: A, CO-1, CO-2, CON, R-1, R-2, R-3, R-4, R-5.

8 districts are not confirmed yet.

Drive-thru rules in plain words

Restaurants with drive-through windows are named in use group 7, which is permitted by right in C-1, C-2, C-4, M-1 and M-2, and Table 17.20.030 agrees with those district lists. A drive-through needs only an Improvement Location Permit after Site Review Committee approval, with no special use step. In C-1 and C-2, sale and preparation must take place in an enclosed building. M-3, W-I and AIR allow only a 'drive-in/open air restaurant' (use group 11), and W-R allows only a 'restaurant and refreshment stand' (use group 12). The code does not define these terms, so those districts are unsettled.

Code facts

Jurisdiction
Vanderburgh County, Indiana (unincorporated)
Zoning code
Vanderburgh County Code Title 17, Land Use and Zoning
Code last amended
Most recent amendment seen in the chapters read: May 28, 2024 (Ord. 05-24-005; ch. 17.08 and the new sign chapter 17.26). The code host's own currency page could not be fetched.
Restaurant parking
One space for each six customer seats (17.24.080(A)(7)(a); same ratio for use group 12 at (A)(12)(a)). Lots of 30+ spaces need one landscaped island per 15 spaces, and lots of 60+ spaces need one tree per 30 spaces (17.24.120).
Drive-thru stacking
No drive-through stacking or queuing standard found in chapters 17.12, 17.13, 17.24 or 17.26.
Signs
Table 17.26.250.A: total sign area 250 sq ft in C-1, 400 in C-2, 500 in C-4 and M/W-I. One freestanding sign per street frontage in C-1, 2 in C-2, 3 in C-4/M. Monument signs up to 8 ft; pole signs up to 18 ft in C-1 and 50 ft in C-2/C-4/M. Up to two drive-through signs per drive-through aisle (menu boards/intercom) need no permit and do not count toward totals (17.26.235.A.4). They must face the drive-thru lane (17.26.270.B.3).
Typical approval time
Code timings only: each Site Review Committee member has 12 business days to act, and the ILP must be obtained within 12 months of Site Review approval (17.36.020). For a rezoning, the APC hearing comes within 60 days, its report within 30 days, and the County Commission vote within 90 days (17.36.040-060).
Official code
codepublishing.com
Planning office
Evansville-Vanderburgh County Area Plan Commission evansvilleapc.com

Approvals and how long they take

ApprovalWho decidesStepsTypical timeFeeSection
Improvement Location Permit with Site Review (by-right drive-through)Area Plan Commission Director, after Site Review Committee approvalSubmit an ILP application with a scaled site plan showing property lines, access drives/curb cuts, parking and loading, landscape islands, signs and fences. Site Review (APC Director, Building Commissioner, County Surveyor, County Engineer, water/sewer utility, Health Dept. as needed) meets weekly; the applicant's representative must attend. The Director then issues the ILP. Site Review decisions can be appealed to the BZA.12 business days per Site Review member; ILP must be obtained within 12 months of approvalSet by the APC fee schedule (doubled if work starts before the permit)17.36.020; 17.36.140 source
Special useBoard of Zoning Appeals after a public hearingPetition and public hearing with published notice paid for by the petitioner. No restaurant or drive-in special use exists in 17.28.050, so this route does not apply to a drive-through restaurant.17.36.090; 17.28 source
Rezoning (e.g. to C-2 or C-4)Area Plan Commission recommends; County Commission decidesFile the petition, location map, ordinance, site plan and abutting-owner list at least 21 days before the first County Commission reading. Notice is published, posted and mailed. APC hearing and recommendation, then County Commission vote. Written commitments are allowed. A denial bars refiling for 12 months.APC hearing within 60 days; report within 30 days; County Commission vote within 90 days17.36.040-17.36.070 source
Variance (dimensional only)Board of Zoning AppealsPetition with a site plan and a public hearing; the BZA must make all six required findings. No use variances. A denial bars refiling for 12 months.17.36.100; 17.36.120 source

District standards

DistrictNameSetbacksMax heightMax coverageRestaurantRetailGas stationCar washGrocerySection
C-1Light commercialFront 10 ft (lots on dedicated street ROW; see 17.12.050(J)); side 5 ft; corner side 10 ft35 ft75%By rightBy rightNot confirmedNot confirmedBy right17.16.110; 17.20.100; 17.38.010 (Table A) source
C-2Community commercialFront 10 ft; side none (see 17.12.050(H)); corner side 5 ft50 ft75%By rightBy rightNot confirmedNot confirmedBy right17.16.120; 17.20.100-110; 17.38.010 (Table A) source
C-4General commercialFront 10 ft; side none (see 17.12.050(H)); corner side 5 ft50 ft75%By rightBy rightNot confirmedNot confirmedBy right17.16.130; 17.20.100-140; 17.38.010 (Table A) source
M-1Light industrialFront 10 ft; side none (see 17.12.050(I)); corner side 5 ft50 ft for commercial use groups (C-4 limit); none otherwise75%By rightBy rightNot confirmedNot confirmedBy right17.16.160; 17.38.010 (Table A) source
M-2General industrialFront 10 ft; side none (see 17.12.050(I)); corner side 5 ft50 ft for commercial use groups (C-4 limit); none otherwise75%By rightBy rightNot confirmedNot confirmedBy right17.16.170; 17.38.010 (Table A) source
M-3Heavy industrialFront 10 ft; side none (see 17.12.050(I)); corner side 5 ft50 ft for use groups 10-11 (C-4 limit); none otherwise75%Not confirmedNot confirmedNot confirmedNot confirmedNot allowed17.16.180; 17.38.010 (Table A) source
W-IWaterfront industrialFront 10 ft; side none (see 17.12.050(I)); corner side 5 ftNone in Table A75%Not confirmedNot confirmedNot confirmedNot confirmedNot allowed17.16.150; 17.38.010 (Table A) source
W-RWaterfront recreational/residentialFront 20 ft; side none; corner side 5 ft35 ft75%By rightNot confirmedNot confirmedNot confirmedNot allowed17.16.140; 17.20.150; 17.38.010 (Table A) source

Overlays to watch

Second check against the source text: 2026-11-25 (Table 17.20.030 was partly read. In the published text the table is flattened, so individual X marks cannot be pinned to use-group columns. There are no special-use marks; X is the only mark. The number of X marks in every row (A 5, R-1 2, R-2 3, R-3 4, R-4 5, R-5 5, CO-1/CO-2 6, C-1 5, C-2 5, C-4 8, M-1 9, M-2 10, M-3 7, W-I 6, W-R 6) exactly matches the number of use groups that list that district in their 17.20 headings and in 17.16 (A). So the table agrees that use group 7 is permitted in C-1, C-2, C-4, M-1 and M-2 and in no other district, and those rows were raised to high confidence on the strength of 17.20.100 and 17.16.110-170, read directly. The F-1 row has 10 X marks that cannot be aligned to columns; AIR and CON have no rows. Other corrections: quotes replaced with district-specific text. CON changed to prohibited (17.16.030 limits it to groups 17-18). CO-1, CO-2 and A raised to high from their 17.16 use lists. C-1/C-2 enclosed-building rule added. Table A dimensions added. Approvals, signs and parking landscaping added. Code last amended May 28, 2024 is the latest date seen. The APC website (evansvilleapc.com) could not be fetched (robots unreachable), so no phone number or fees. Shell download of codepublishing.com was blocked by the sandbox proxy and not worked around. gas_station and car_wash were left unclear: automotive service stations are in use group 8, but the special-use list mentions gasoline sales (SU 16) and that was not re-read.).

Drive-thru restaurant rule by zoning district

DistrictDrive-thru restaurantWhat the code saysSectionSourceRead on
A
Agricultural district
Not allowedUse group 2-subject to the restrictions provided in Section 17.16.040(A)(2);
A permits use groups 1, 2, 17, 18 and 19 (19 only as Special Use No. 25, for farm-product processing and sales). No restaurant use group applies.
17.16.020; Table 17.20.030codepublishing.com2026-11-25
AIR
Airport district
Not confirmedNot read closely enough to state a rule.codepublishing.com2026-11-25
C-1
Light commercial (17.08.050; called Neighborhood commercial in 17.16.110)
By right(including restaurants with drive-through windows)
Use group 7 is permitted in C-1 with no special use step. In C-1, all sale, display, preparation and storage must take place inside a fully enclosed building (17.16.110). Needs an Improvement Location Permit after Site Review (17.36.020). Table A: max height 35 ft, front yard 10 ft, side yard 5 ft, corner side 10 ft, max lot coverage 75%. Parking: 1 space per 6 customer seats (17.24.080(A)(7)(a)). No drive-through stacking rule found.
17.20.100 (use group 7, C. service uses); 17.16.110; Table 17.20.030codepublishing.com2026-11-25
C-2
Community commercial
By rightC-1, C-2, C-4, M-1, and M-2 districts
Use group 7 (includes restaurants with drive-through windows) is permitted with no special use step. Same enclosed-building rule as C-1 (17.16.120). ILP after Site Review. Table A: max height 50 ft, front yard 10 ft, no side yard (see 17.12.050(H)), corner side 5 ft, max lot coverage 75%. Parking 1 per 6 seats.
17.20.100 (use group 7 heading); 17.16.120; Table 17.20.030codepublishing.com2026-11-25
C-3
Not a Title 17 district
Not confirmedNot read closely enough to state a rule.codepublishing.com2026-11-25
C-4
General commercial
By right(including restaurants with drive-through windows)
Permitted through use group 7, and a drive-in/open air restaurant is also permitted through use group 11. The enclosed-building rule applies except to use group 11 uses (17.16.130). ILP after Site Review. Table A: max height 50 ft, front yard 10 ft, no side yard (see 17.12.050(H)), corner side 5 ft, max lot coverage 75%.
17.20.100 (use group 7); 17.20.140 (use group 11); 17.16.130; Table 17.20.030codepublishing.com2026-11-25
CO-1
Commercial office
Not allowedUse group 1; 2. Use group 3; 3. Use group 4;
CO-1 permits use groups 1, 3, 4, 5, 6 and 20 only; none lists restaurants. Office buildings capped at 3,000 sq ft. Would need a rezoning, or the Area Plan Commission adding a use to a group (17.20.020).
17.16.090; Table 17.20.030codepublishing.com2026-11-25
CO-2
Commercial office
Not allowedUse group 1; 2. Use group 3; 3. Use group 4;
CO-2 permits use groups 1, 3, 4, 5, 6 and 20 only; none lists restaurants.
17.16.100; Table 17.20.030codepublishing.com2026-11-25
CON
Conservancy district
Not allowedUse group 17; 2. Use group 18; 3. Special uses;
17.16.030 limits CON to use groups 17 and 18 (agricultural/open uses), special uses and accessory uses; no restaurant use. CON is not in the 17.08.050 district list or Table 17.20.030 and was not seen on the county layer.
17.16.030; 17.20.200-210codepublishing.com2026-11-25
F-1
Floodway district
Not confirmedNot read closely enough to state a rule.codepublishing.com2026-11-25
M-1
Light industrial
By rightC-1, C-2, C-4, M-1, and M-2 districts
Use groups 7 and 11 are permitted. Commercial use groups (5, 7-11) in M-1 must meet C-4 height and lot coverage limits (50 ft, 75%) (17.16.160). Table A front yard 10 ft, corner side 5 ft. ILP after Site Review.
17.20.100 (use group 7 heading); 17.16.160; Table 17.20.030codepublishing.com2026-11-25
M-2
General industrial
By rightC-1, C-2, C-4, M-1, and M-2 districts
Use groups 7 and 11 are permitted. Commercial use groups 7-11 in M-2 must meet C-4 height and lot coverage limits (50 ft, 75%) (17.16.170). Table A front yard 10 ft, corner side 5 ft. ILP after Site Review.
17.20.100 (use group 7 heading); 17.16.170; Table 17.20.030codepublishing.com2026-11-25
M-3
Heavy industrial
Not confirmedNot read closely enough to state a rule.codepublishing.com2026-11-25
PUD
Planned unit development
Not confirmedNot read closely enough to state a rule.codepublishing.com2026-11-25
R-1
One-family residence
Not allowedOne-family residence
Residential district; only use groups 1 and 2 apply.
17.08.050; 17.20.040-050 (use groups 1-2); Table 17.20.030codepublishing.com2026-11-25
R-2
Two-family residence
Not allowedTwo-family residence
Residential district; only use groups 1, 2 and 3 apply.
17.08.050; use groups 1-3; Table 17.20.030codepublishing.com2026-11-25
R-3
Multiple residential
Not allowedR-3, R-4, R-5, CO-1, CO-2, C-1, C-2, and W-R districts
Residential district; only use groups 1-4 apply.
17.20.070 (use group 4); Table 17.20.030codepublishing.com2026-11-25
R-3A
Not a Title 17 district
Not confirmedNot read closely enough to state a rule.codepublishing.com2026-11-25
R-4
Multiple residential
Not allowedR-4, R-5, CO-1, CO-2, C-1, and C-2 districts
Residential district; only use groups 1, 2, 3, 4 and 6 apply.
17.20.090 (use group 6); Table 17.20.030codepublishing.com2026-11-25
R-5
Multiple residential
Not allowedR-4, R-5, CO-1, CO-2, C-1, and C-2 districts
Residential district; only use groups 1, 2, 3, 4 and 6 apply.
17.20.090 (use group 6); Table 17.20.030codepublishing.com2026-11-25
W-I
Waterfront industrial
Not confirmedNot read closely enough to state a rule.codepublishing.com2026-11-25
W-R
Waterfront recreational/residential
Not confirmedNot read closely enough to state a rule.codepublishing.com2026-11-25

"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.

Official zoning map layer

To find the district for a parcel, query the jurisdiction's own GIS zoning layer: https://maps.evansvillegis.com/arcgis_server/rest/services/PROPERTY/ZONING/MapServer/0 (district field: Zoning_District)

Shared Evansville-Vanderburgh zoning layer. The draft's earlier county query (Municipality='VC') returned A, C-1, C-2, C-3, C-4, CO-1, CO-2, M-1, M-2, M-3, PUD, R-1, R-2, R-3, R-3A, R-4, R-5, W-I, W-R; the layer was not re-queried in this pass. C-3 and R-3A are not districts in Title 17 (17.08.050). AIR, CON and F-1 are in the code but did not show up in that query.

Sources

How to confirm before you buy

  1. Look up the parcel on the official zoning map to get its district and any overlay.
  2. Open the code section linked in the table and read the use table and the drive-thru standards.
  3. Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.

Why this library exists

I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.