Rural Vacant LandZoning Library
Zoning Library › Arizona › Tempe, AZ

Tempe, AZ zoning: where a drive-thru restaurant is allowed

Maricopa County · 33 districts on file · last read 2026-11-19 · data.json

Is a drive-thru allowed in Tempe, AZ?

A drive-thru restaurant is allowed by right (no conditional use permit, special exception or rezoning) in these zoning districts: MU-4, PCC-1, PCC-2, RCC.

It needs a conditional or special use approval in: CSS, GID, HID, LID, MU-3, MU-ED.

It is not allowed in 19 districts: AG, MHS, MU-1, MU-2, R1-4, R1-5, R1-6, R1-7, R1-8, R1-10, R1-15, R-2, R-3, R-3R, R-4, R-5, RMH, RO, TP.

4 districts are not confirmed yet.

Drive-thru rules in plain words

For restaurants, Tables 3-202A and 3-202B have a sub-row under Restaurants for drive-in/drive-through use: permitted with standards in PCC-1, PCC-2, RCC and MU-4, use permit in CSS, MU-3 and MU-Ed, and no in R/O, MU-1, MU-2. CC is unsettled because a second generic drive-through row disagrees. Industrial districts require a use permit via a catch-all row.

Code facts

Jurisdiction
City of Tempe Zoning and Development Code (ZDC)
Zoning code
Zoning and Development Code
Code last amended
Table 3-202A history on Zoneomics lists Ord. O2022.27, O2025.23 (7-1-2025) and O2026.23 (6-4-2026); Table 3-202B lists O2026.22 (6-4-2026). Not confirmed on an official copy.
Drive-thru stacking
Section 3-408 as read has no stacking or queue length number. It sets lane width (9 ft), pedestrian-conflict design, shade for south/west pick-up windows, a 20 ft street buffer and a 3 ft screen wall.
Official code
tempe.gov
Official zoning map
gis.tempe.gov
Planning office
City of Tempe Community Development, Planning tempe.gov

Approvals and how long they take

ApprovalWho decidesStepsTypical timeFeeSection
Use permit (incl. use permit standard)Not confirmedSubmit application and checklist; review process flow chart is in the city's packet. Criteria are in Section 6-308 per that packet.6-308 source

Overlays to watch

Second check against the source text: 2026-11-19 (Official tempe.gov ZDC PDFs could not be found (the city links out to a third-party code host that was not read); tempe.gov pages hold only old or partial copies. All use rows come from Zoneomics, confirmed against partial city/ordinance copies. CC left unclear. Found the first pass quoted the generic drive-through row instead of the Restaurants sub-row. MHS fixed to prohibited.).

Drive-thru restaurant rule by zoning district

DistrictDrive-thru restaurantWhat the code saysSectionSourceRead on
AG
Agricultural
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
CC
City Center
Not confirmedNot read closely enough to state a rule.zoneomics.com2026-11-19
COUNTY
County (unincorporated island zoning)
Not confirmedNot read closely enough to state a rule.gis.tempe.gov2026-11-19
CSS
Commercial Shopping and Service
ConditionalWith drive-in or drive-through, [Section 3-408] N U(S) N S S S
Use permit required, with special standards. Standards in Section 3-408: drive lanes at least 9 ft wide on straight runs; limit conflicts with pedestrian paths; shade at south or west pick-up windows; 20 ft landscape buffer and 3 ft screen wall where street-facing. Same result in the generic drive-through row.
3-202A; 3-408zoneomics.com2026-11-19
GID
General Industrial
ConditionalRetail and Restaurant Uses - and all other uses under Table 3-202A
Catch-all row sends restaurants to Table 3-202A rules but marks LID/GID/HID as U (use permit). No separate drive-through row in Table 3-302A (checked twice).
3-302Azoneomics.com2026-11-19
GLUPE
Guadalupe
Not confirmedNot read closely enough to state a rule.gis.tempe.gov2026-11-19
HID
Heavy Industrial
ConditionalRetail and Restaurant Uses - and all other uses under Table 3-202A
Catch-all row sends restaurants to Table 3-202A rules but marks LID/GID/HID as U (use permit). No separate drive-through row in Table 3-302A (checked twice).
3-302Azoneomics.com2026-11-19
LID
Light Industrial
ConditionalRetail and Restaurant Uses - and all other uses under Table 3-202A
Catch-all row sends restaurants to Table 3-202A rules but marks LID/GID/HID as U (use permit). No separate drive-through row in Table 3-302A (checked twice).
3-302Azoneomics.com2026-11-19
MHS
Manufactured Housing Subdivision
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Falls in the MH/RMH/TP column of Table 3-102, which has no restaurant row. MHS is not in the GIS domain. Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
MU-1
Mixed-Use, Low-Medium Density
Not allowedWith drive-in or drive-through [Section 3-408] N N U(S) S U(S)
N. MU-1 is not in the GIS zoning domain.
3-202B; 3-408zoneomics.com2026-11-19
MU-2
Mixed-Use, Medium Density
Not allowedWith drive-in or drive-through [Section 3-408] N N U(S) S U(S)
N.
3-202B; 3-408zoneomics.com2026-11-19
MU-3
Mixed-Use, Medium-High Density
ConditionalWith drive-in or drive-through [Section 3-408] N N U(S) S U(S)
Use permit required with special standards. Section 3-201 also says restaurants with drive-through need a use permit in MU-3. Standards in Section 3-408: drive lanes at least 9 ft wide on straight runs; limit conflicts with pedestrian paths; shade at south or west pick-up windows; 20 ft landscape buffer and 3 ft screen wall where street-facing.
3-202B; 3-408zoneomics.com2026-11-19
MU-4
Mixed-Use, High Density
By rightWith drive-in or drive-through [Section 3-408] N N U(S) S U(S)
Standards in Section 3-408: drive lanes at least 9 ft wide on straight runs; limit conflicts with pedestrian paths; shade at south or west pick-up windows; 20 ft landscape buffer and 3 ft screen wall where street-facing.
3-202B; 3-408zoneomics.com2026-11-19
MU-ED
Mixed-Use Educational (code label MU-Ed; GIS value MU-ED)
ConditionalWith drive-in or drive-through [Section 3-408] N N U(S) S U(S)
Use permit required with special standards. Standards in Section 3-408: drive lanes at least 9 ft wide on straight runs; limit conflicts with pedestrian paths; shade at south or west pick-up windows; 20 ft landscape buffer and 3 ft screen wall where street-facing.
3-202B; 3-408zoneomics.com2026-11-19
PCC-1
Planned Commercial Center Neighborhood
By rightWith drive-in or drive-through, [Section 3-408] N U(S) N S S S
Standards in Section 3-408: drive lanes at least 9 ft wide on straight runs; limit conflicts with pedestrian paths; shade at south or west pick-up windows; 20 ft landscape buffer and 3 ft screen wall where street-facing. Same result in the generic drive-through row.
3-202A; 3-408zoneomics.com2026-11-19
PCC-2
Planned Commercial Center General
By rightWith drive-in or drive-through, [Section 3-408] N U(S) N S S S
Standards in Section 3-408: drive lanes at least 9 ft wide on straight runs; limit conflicts with pedestrian paths; shade at south or west pick-up windows; 20 ft landscape buffer and 3 ft screen wall where street-facing. Same result in the generic drive-through row.
3-202A; 3-408zoneomics.com2026-11-19
R1-4
Single-Family Residential
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R1-5
Single-Family Residential
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R1-6
Single-Family Residential
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R1-7
Single-Family Residential
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R1-8
Single-Family Residential
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R1-10
Single-Family Residential
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R1-15
Single-Family Residential
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R1-PAD
Single-Family Residential Planned Area Development
Not confirmedNot read closely enough to state a rule.zoneomics.com2026-11-19
R-2
Multi-Family Residential
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R-3
Multi-Family Residential Limited
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R-3R
Multi-Family Residential Restricted
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R-4
Multi-Family Residential General
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
R-5
Multi-Family Residential High Density
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
RCC
Regional Commercial Center
By rightWith drive-in or drive-through, [Section 3-408] N U(S) N S S S
Standards in Section 3-408: drive lanes at least 9 ft wide on straight runs; limit conflicts with pedestrian paths; shade at south or west pick-up windows; 20 ft landscape buffer and 3 ft screen wall where street-facing. Same result in the generic drive-through row.
3-202A; 3-408zoneomics.com2026-11-19
RMH
Mobile Home Residence
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19
RO
Residential/Office (code label R/O; GIS value RO)
Not allowedWith drive-in or drive-through, [Section 3-408] N U(S) N S S S
Restaurant drive-through shown as N.
3-202A; 3-408zoneomics.com2026-11-19
TP
Trailer Park
Not allowedKey: P = Permitted S = Permitted with special standards or limitations U = Use permit required N = Not permitted
Table 3-102, the residential use table, has no restaurant or drive-through row, so the use is not permitted here.
3-102 (Table 3-102 key)zoneomics.com2026-11-19

"By right" means permitted with site plan and building permit review only. Overlay districts, planned developments (PD/PUD) and conditions attached to a past rezoning can change the answer for a single parcel.

Official zoning map layer

To find the district for a parcel, query the jurisdiction's own GIS zoning layer: https://gis.tempe.gov/arcgis/rest/services/Open_Data/Zoning_Districts/MapServer/0 (district field: ZoningCode)

Layer metadata read (MapServer/0?f=pjson). Distinct-value queries were refused (client_error / 403), so values come from the ZoningCode coded-value domain (31 values): CC, COUNTY, CSS, HID, LID, MU-2, MU-3, MU-4, MU-ED, PCC-1, PCC-2, R1-10, R1-15, R1-4, R1-5, R1-6, R1-7, R1-8, R1-PAD, R-2, R-3, R-3R, R-4, RCC, RMH, RO, TP, GLUPE, AG, GID, R-5. Renderer lists 29 of these (no COUNTY, GLUPE). The domain has no MU-1 or MHS; MU-1 and MHS are kept as code districts. The GIS spells R/O as RO and MU-Ed as MU-ED. A FeatureServer copy exists at the same host (Open_Data/Zoning_Districts/FeatureServer/0); it was not queried successfully. PAD or overlay suffixes may exist in real data beyond the domain.

Sources

How to confirm before you buy

  1. Look up the parcel on the official zoning map to get its district and any overlay.
  2. Open the code section linked in the table and read the use table and the drive-thru standards.
  3. Call the planning office and ask whether a drive-thru restaurant needs anything beyond site plan review at that address.

Why this library exists

I'm Luke Smith. I find land for drive-thru brands like 7 Brew, Ellianos Coffee and Starbucks, sign the tenant, build the shop and sell it as a net lease property. Every deal starts with the same question: is the use allowed here without a rezoning? Getting that answer takes too long, so we read the codes (with AI research help), and I publish what we find with a link back to every source so you can check it yourself.

If you have a site that fits a drive-thru, or you want to learn how these deals are put together, join the free Reverse Deal Finder community on Skool, see cap rates and land prices by brand, or call 1-760-392-1525. Brokers welcome: I pay commissions.