 "jurisdiction": "Cary, NC",
 "state": "NC",
 "counties": [
  "Wake"
 ],
 "url": "https://ruralvacantland.com/zoning/nc/cary/",
 "publisher": "Rural Vacant Land (ruralvacantland.com)",
 "use": "drive-thru restaurant",
 "last_read": "2026-11-15",
 "summary": "We have not confirmed any zoning district in Cary, NC where a drive-thru restaurant is allowed by right. It is not allowed in 2 districts: CT, OI. 15 districts are not confirmed yet.",
 "status_meaning": {
  "by_right": "Allowed by right",
  "conditional": "Needs a conditional or special use approval",
  "prohibited": "Not allowed",
  "unclear": "Not confirmed yet"
 },
 "zoning_layer": {
  "url": "https://maps.townofcary.org/arcgis/rest/services/LandUse/Zoning/MapServer/11",
  "district_field": "ZONECLASS"
 },
 "districts": [
  {
   "district": "CT",
   "name": "Corridor Transitional District (Walnut Street Corridor)",
   "status": "prohibited",
   "quote": "Such uses do not have a drive-up window, nor an outside amphitheater, stage or other provision...",
   "code_section": "5.2.3(K)(5)(d)",
   "conditions": "In CT, restaurants (indoor and/or outdoor) are allowed only in the Redevelopment Area and first 300 ft of the Infill Area, with office or personal services as the building's principal use, at most 20% of building area, one separate customer entrance, and no drive-up window. A drive-through restaurant therefore does not qualify. Deduced from the standard's own text.",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "GC",
   "name": "General Commercial District",
   "status": "unclear",
   "quote": "",
   "code_section": "4.2.2 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_4",
   "read_on": "2026-11-15"
  },
  {
   "district": "I",
   "name": "Industrial District",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "MXD",
   "name": "Mixed Use District",
   "status": "unclear",
   "quote": "",
   "code_section": "Table 5.1-1 note 1 / 4.5",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "OI",
   "name": "Office and Institutional District",
   "status": "prohibited",
   "quote": "The use does not have a drive-up window, nor an outside amphitheater, stage, or other provision...",
   "code_section": "5.2.3(K)(1)(d)",
   "conditions": "Restaurants are a permitted use in OI only when all 5.2.3(K)(1) conditions are met: the building's principal use is office, restaurant/retail is at most 20% of gross floor area, at most one customer entrance separate from the office entrance, and no drive-up window or outdoor stage/amplified entertainment. So a sit-down restaurant inside an office building is allowed, but a drive-through restaurant is not. Deduced from the standard's own text.",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "ORD",
   "name": "Office/Research and Development District",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "PDD (Major)",
   "name": "Major Planned Development District",
   "status": "unclear",
   "quote": "",
   "code_section": "4.5 / 3.4.3",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_4",
   "read_on": "2026-11-15"
  },
  {
   "district": "PDD (Minor)",
   "name": "Minor Planned Development District",
   "status": "unclear",
   "quote": "",
   "code_section": "4.5 / 3.4.3",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_4",
   "read_on": "2026-11-15"
  },
  {
   "district": "R-8",
   "name": "Residential District R-8",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "R-12",
   "name": "Residential District R-12",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "R-20",
   "name": "Residential District R-20",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "R-40",
   "name": "Residential District R-40",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "R-80",
   "name": "Residential District R-80",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "RMF",
   "name": "Multi-Family Residential District",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "RR",
   "name": "Resource/Recreation District",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  },
  {
   "district": "TC",
   "name": "Town Center District",
   "status": "unclear",
   "quote": "",
   "code_section": "5.2.3(K)(2)-(3) / Table 5.1-2",
   "conditions": "",
   "source_url": "https://codelibrary.amlegal.com/codes/cary/latest/cary_nc/0-0-0-68616",
   "read_on": "2026-11-15"
  },
  {
   "district": "TR",
   "name": "Transitional Residential District",
   "status": "unclear",
   "quote": "",
   "code_section": "5.1.1 / Table 5.1-1",
   "conditions": "",
   "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
   "read_on": "2026-11-15"
  }
 ],
 "profile": {
  "official_name": "Town of Cary, North Carolina",
  "code_title": "Town of Cary Land Development Ordinance (LDO)",
  "official_code_url": "https://codelibrary.amlegal.com/codes/cary",
  "code_last_amended": "Town LDO page (read 2026-11-15) lists amendments approved since the last electronic update, newest Act 31 approved 2023-11-16, and warns the online LDO may not reflect the most current amendments. Earlier pass saw an American Legal editor's note dated to 2020-LDO-01 (5-7-20); not re-read.",
  "zoning_map_url": "https://maps.townofcary.org/arcgis/rest/services/LandUse/Zoning/MapServer/11",
  "planning_office": {
   "name": "Planning and Development Services, Town of Cary",
   "phone": "311 in Cary; 919-469-4000 outside Cary",
   "url": "https://www.carync.gov/business-development/developing-in-cary/development-regulations/land-development-ordinance"
  },
  "drive_thru_summary": "Cary's LDO has no separate drive-through restaurant use; a drive-through is a feature of a restaurant, which is permitted where Table 5.1-1/5.1-2 shows P. Restaurants allowed in OI, CT and the TC OFC/INS and OFC/IND subdistricts may not have a drive-up window or drive-through (5.2.3(K)). Drive-throughs need 8 stacking spaces from the order box (Table 7.8-3) and canopies oriented away from major roadways (7.7.3(C)(2)).",
  "drive_thru_stacking": "Restaurant with drive-through: minimum 8 stacking spaces measured from the order box, with at least a 4-vehicle queue from order box to pick-up window (LDO 7.8.2(E), Table 7.8-3). Planning Director may let stacking for auto-related uses count toward minimum parking (7.8.2(C)(10)).",
  "parking_restaurant": "1 space per 150 sq ft including outdoor waiting/seating/dining areas, or 1 per 3 persons of maximum fire-rated capacity, whichever is greater (Table 7.8-1).",
  "approvals": [
   {
    "type": "Special Use permit",
    "who_decides": "Zoning Board of Adjustment",
    "steps": "Pre-application conference; application to Planning; staff report; quasi-judicial evidentiary hearing; written decision",
    "section": "3.8",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_3"
   },
   {
    "type": "Development (site) plan",
    "who_decides": "Planning Director (administrative) or Town Council/ZBA for plans requiring a hearing",
    "steps": "Pre-application conference generally required; administrative plans need no notice; board/Council plans need evidentiary hearing with mailed and posted notice",
    "section": "3.9",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_3"
   },
   {
    "type": "Rezoning / conditional use rezoning",
    "who_decides": "Town Council after Planning and Zoning Board recommendation",
    "steps": "Application; TIA if 100+ peak-hour trips; neighborhood meeting; notice and Council public hearing; P&Z Board recommendation within 90 days; Council decision with consistency statement",
    "section": "3.4",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_3"
   }
  ],
  "districts": {
   "OI": {
    "name": "Office and Institutional",
    "min_lot": "none specified",
    "setbacks": "30 ft from street right-of-way (15 ft from private street in OI); no side/rear minimum",
    "max_height": "35 ft within 100 ft of residential district, else 50 ft (+1 ft per extra ft of setback)",
    "restaurant": "by_right",
    "retail": "by_right",
    "section": "Table 6.1-2; 5.2.3(K)(1)",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_6"
   },
   "GC": {
    "name": "General Commercial",
    "min_lot": "none specified",
    "setbacks": "30 ft from street right-of-way; no side/rear minimum",
    "max_height": "35 ft within 100 ft of residential district, else 50 ft",
    "restaurant": "unclear",
    "section": "Table 6.1-2",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_6"
   },
   "ORD": {
    "name": "Office/Research and Development",
    "min_lot": "none specified",
    "setbacks": "30 ft from street right-of-way; no side/rear minimum",
    "max_height": "35 ft within 100 ft of residential district, else 50 ft",
    "restaurant": "unclear",
    "section": "Table 6.1-2",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_6"
   },
   "I": {
    "name": "Industrial",
    "min_lot": "none specified",
    "setbacks": "30 ft from street right-of-way; no side/rear minimum",
    "max_height": "35 ft within 100 ft of residential district, else 50 ft",
    "restaurant": "unclear",
    "section": "Table 6.1-2",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_6"
   }
  },
  "overlays": [
   {
    "name": "Mixed Use Overlay District (Neighborhood, Community, Regional activity centers: NC, CC, RC)",
    "effect": "Adds its own columns to Table 5.1-1 (uses allowed in the overlay on top of the base district); restaurant marks not mapped to these columns.",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_4"
   },
   {
    "name": "Conservation Residential, Thoroughfare, Airport, Watershed Protection, Historic Preservation overlays",
    "effect": "Listed in 4.4.1; overlay rules control over base standards where they conflict (4.1.2); restaurant effect not read.",
    "source_url": "https://www.zoneomics.com/code/cary-NC/chapter_4"
   }
  ],
  "sources": [
   {
    "title": "Cary LDO Ch.5 Use Regulations (American Legal PDF)",
    "url": "https://files.amlegal.com/pdffiles/Cary_pdf/LDO_Ch05.pdf",
    "read_on": "2026-11-15"
   },
   {
    "title": "Cary LDO Ch.5 (Zoneomics copy)",
    "url": "https://www.zoneomics.com/code/cary-NC/chapter_5",
    "read_on": "2026-11-15"
   },
   {
    "title": "Cary LDO 5.1 Tables of Permitted Uses (American Legal)",
    "url": "https://codelibrary.amlegal.com/codes/cary/latest/cary_nc/0-0-0-68594",
    "read_on": "2026-11-15"
   },
   {
    "title": "Cary LDO 5.1.3 Table 5.1-2 TC District uses (American Legal)",
    "url": "https://codelibrary.amlegal.com/codes/cary/latest/cary_nc/0-0-0-68616",
    "read_on": "2026-11-15"
   },
   {
    "title": "Cary LDO Ch.4 Zoning Districts (Zoneomics copy)",
    "url": "https://www.zoneomics.com/code/cary-NC/chapter_4",
    "read_on": "2026-11-15"
   },
   {
    "title": "Cary LDO Ch.3 Procedures (Zoneomics copy)",
    "url": "https://www.zoneomics.com/code/cary-NC/chapter_3",
    "read_on": "2026-11-15"
   },
   {
    "title": "Cary LDO Ch.6 Dimensional standards (Zoneomics copy)",
    "url": "https://www.zoneomics.com/code/cary-NC/chapter_6",
    "read_on": "2026-11-15"
   },
   {
    "title": "Cary LDO Ch.7 Design standards, parking, stacking (Zoneomics copy)",
    "url": "https://www.zoneomics.com/code/cary-NC/chapter_7",
    "read_on": "2026-11-15"
   },
   {
    "title": "Cary LDO Ch.12 Definitions (Zoneomics copy)",
    "url": "https://www.zoneomics.com/code/cary-NC/chapter_12",
    "read_on": "2026-11-15"
   },
   {
    "title": "Town of Cary LDO page",
    "url": "https://www.carync.gov/business-development/developing-in-cary/development-regulations/land-development-ordinance",
    "read_on": "2026-11-15"
   },
   {
    "title": "Town of Cary Permitted Uses & Setbacks page",
    "url": "https://www.carync.gov/business-development/developing-in-cary/development-guidelines/permitted-uses-setbacks",
    "read_on": "2026-11-15"
   }
  ],
  "verified": {
   "on": "2026-11-15",
   "by": "opus",
   "checked": 17,
   "corrected": 3,
   "notes": "Re-read Ch.5 (Table 5.1-1 headers/legend, 5.1.1, 5.2.3(K)), Table 5.1-2, Ch.3, 4, 6, 7, 12 and town pages. Corrections: TC note expanded with subdistrict list and kept unclear; added MXD district; residential/RR/ORD/I/GC confidence set low (not 'not read') since the table was read but cell positions are lost; added stacking (8 spaces), parking, setbacks/height, approvals. OI and CT kept prohibited (medium) from 5.2.3(K). GIS distinct values still not obtained (robots.txt / proxy)."
  }
 },
 "fees": null,
 "note": "Summary of the public zoning code with links to each source. Not legal advice; confirm with the planning office."
}