 "jurisdiction": "San Tan Valley, AZ",
 "state": "AZ",
 "counties": [
  "Pinal"
 ],
 "url": "https://ruralvacantland.com/zoning/az/san-tan-valley/",
 "publisher": "Rural Vacant Land (ruralvacantland.com)",
 "use": "drive-thru restaurant",
 "last_read": "2026-11-23",
 "summary": "A drive-thru restaurant is allowed by right (no conditional use permit, special exception or rezoning) in these zoning districts: C-3, I-2. It needs a conditional or special use approval in: C-1, C-2, I-1, I-3. It is not allowed in 17 districts: AR, GR, MHP, MHS, P/OS, PF, R1-7, R1-9, R1-12, R1-20, R1-35, R1-43, R-2, R-3, R-4, R-5, RD. 4 districts are not confirmed yet.",
 "status_meaning": {
  "by_right": "Allowed by right",
  "conditional": "Needs a conditional or special use approval",
  "prohibited": "Not allowed",
  "unclear": "Not confirmed yet"
 },
 "zoning_layer": {
  "url": "https://services7.arcgis.com/taxrXv3wELVrPFY3/arcgis/rest/services/SanTanValley_ZoningOrd_gdb/FeatureServer/9",
  "district_field": "Zoning_STV_Label"
 },
 "districts": [
  {
   "district": "AR",
   "name": "Agriculture/Rural Development",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "C-1",
   "name": "Neighborhood Commercial",
   "status": "conditional",
   "quote": "Drive Through C C P 3.1.10 ... Restaurant C P P",
   "code_section": "Table 2.3-1; 3.1.10; 6.7",
   "conditions": "Both Restaurant and Drive Through are C (conditional use permit) in C-1. Sec. 3.1.10: drive-through at least 25 ft from public right-of-way and 500 ft from a residential district (closer requires a use permit); restaurant lanes need 40 ft entry-to-order board and 100 ft order-to-pickup window, 4 queuing spaces per window (2 per lane if double), 12-ft lane width, 25-ft inner turning radius, 300-ft separation between drive-through entries, 3-4 ft wall/hedge screening with 3-ft planters, solid canopy 20 ft (30 ft if window faces a street) over pickup window, speakers inaudible from residential property. Town Engineer may require a queuing study.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "C-2",
   "name": "Community Commercial",
   "status": "conditional",
   "quote": "Drive Through C C P 3.1.10",
   "code_section": "Table 2.3-1; 3.1.10; 6.7",
   "conditions": "Restaurant is P but the Drive Through use is C (conditional use permit: P&Z recommends, Town Council decides). Sec. 3.1.10: drive-through at least 25 ft from public right-of-way and 500 ft from a residential district (closer requires a use permit); restaurant lanes need 40 ft entry-to-order board and 100 ft order-to-pickup window, 4 queuing spaces per window (2 per lane if double), 12-ft lane width, 25-ft inner turning radius, 300-ft separation between drive-through entries, 3-4 ft wall/hedge screening with 3-ft planters, solid canopy 20 ft (30 ft if window faces a street) over pickup window, speakers inaudible from residential property. Town Engineer may require a queuing study.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "C-3",
   "name": "Regional Commercial",
   "status": "by_right",
   "quote": "Drive Through C C P 3.1.10 ... Restaurant C P P",
   "code_section": "Table 2.3-1; 3.1.10",
   "conditions": "Restaurant and Drive Through both P, subject to Sec. 3.1.10 standards and site plan review; a drive-through less than 500 ft from a residential district requires a use permit. Sec. 3.1.10: drive-through at least 25 ft from public right-of-way and 500 ft from a residential district (closer requires a use permit); restaurant lanes need 40 ft entry-to-order board and 100 ft order-to-pickup window, 4 queuing spaces per window (2 per lane if double), 12-ft lane width, 25-ft inner turning radius, 300-ft separation between drive-through entries, 3-4 ft wall/hedge screening with 3-ft planters, solid canopy 20 ft (30 ft if window faces a street) over pickup window, speakers inaudible from residential property. Town Engineer may require a queuing study.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "CBD",
   "name": "Central Business District",
   "status": "unclear",
   "quote": "",
   "code_section": "2.5.7 (mentions CBD); not in Table 2.1-1",
   "conditions": "",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "GR",
   "name": "General Rural",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "I-1",
   "name": "Office/Business Park",
   "status": "conditional",
   "quote": "Restaurant P P C / Drive Through C P C 3.1.10",
   "code_section": "Table 2.4-1; 3.1.10; 6.7",
   "conditions": "Restaurant P but Drive Through C (conditional use permit). Sec. 3.1.10: drive-through at least 25 ft from public right-of-way and 500 ft from a residential district (closer requires a use permit); restaurant lanes need 40 ft entry-to-order board and 100 ft order-to-pickup window, 4 queuing spaces per window (2 per lane if double), 12-ft lane width, 25-ft inner turning radius, 300-ft separation between drive-through entries, 3-4 ft wall/hedge screening with 3-ft planters, solid canopy 20 ft (30 ft if window faces a street) over pickup window, speakers inaudible from residential property. Town Engineer may require a queuing study.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "I-2",
   "name": "Light Industrial",
   "status": "by_right",
   "quote": "Restaurant P P C / Drive Through C P C 3.1.10",
   "code_section": "Table 2.4-1; 3.1.10",
   "conditions": "Restaurant and Drive Through both P, subject to Sec. 3.1.10 and site plan review; within 500 ft of a residential district a use permit is required. Sec. 3.1.10: drive-through at least 25 ft from public right-of-way and 500 ft from a residential district (closer requires a use permit); restaurant lanes need 40 ft entry-to-order board and 100 ft order-to-pickup window, 4 queuing spaces per window (2 per lane if double), 12-ft lane width, 25-ft inner turning radius, 300-ft separation between drive-through entries, 3-4 ft wall/hedge screening with 3-ft planters, solid canopy 20 ft (30 ft if window faces a street) over pickup window, speakers inaudible from residential property. Town Engineer may require a queuing study.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "I-3",
   "name": "Heavy Industrial",
   "status": "conditional",
   "quote": "Restaurant P P C / Drive Through C P C 3.1.10",
   "code_section": "Table 2.4-1; 3.1.10; 6.7",
   "conditions": "Restaurant and Drive Through both C (conditional use permit). Sec. 3.1.10: drive-through at least 25 ft from public right-of-way and 500 ft from a residential district (closer requires a use permit); restaurant lanes need 40 ft entry-to-order board and 100 ft order-to-pickup window, 4 queuing spaces per window (2 per lane if double), 12-ft lane width, 25-ft inner turning radius, 300-ft separation between drive-through entries, 3-4 ft wall/hedge screening with 3-ft planters, solid canopy 20 ft (30 ft if window faces a street) over pickup window, speakers inaudible from residential property. Town Engineer may require a queuing study.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "MHP",
   "name": "Manufactured Home/RV Park",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "MHS",
   "name": "Manufactured Home Subdivision",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "MPC",
   "name": "Master Planned Community",
   "status": "unclear",
   "quote": "",
   "code_section": "2.3.2",
   "conditions": "",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "P/OS",
   "name": "Parks/Open Space",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "Table 2.5-1",
   "conditions": "Table 2.5-1 (POS column) lists no restaurant or drive-through use.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "PAD",
   "name": "Planned Area Development (Overlay, legacy Pinal County)",
   "status": "unclear",
   "quote": "",
   "code_section": "2.5.6",
   "conditions": "",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "PCD",
   "name": "Planned Community District",
   "status": "unclear",
   "quote": "",
   "code_section": "2.5.5.B.2",
   "conditions": "",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "PF",
   "name": "Public Facilities",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "Table 2.5-1",
   "conditions": "Table 2.5-1 lists no restaurant or drive-through use. Note: Table 2.1-1 calls PF 'Public Facilities' but Sec. 2.5.2 and Table 2.5-1 label it 'FD' / Future Development; same district assumed.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R1-7",
   "name": "Single-Family Residential 7,000",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R1-9",
   "name": "Single-Family Residential 9,000",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R1-12",
   "name": "Single-Family Residential 12,000",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R1-20",
   "name": "Single-Family Residential 20,000",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R1-35",
   "name": "Single-Family Residential 35,000",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R1-43",
   "name": "Single-Family Residential 1-Acre",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R-2",
   "name": "Mixed Residential-2",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R-3",
   "name": "Mixed Residential-3",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R-4",
   "name": "Mixed Residential-4",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "R-5",
   "name": "Multi-Family Residential",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  },
  {
   "district": "RD",
   "name": "Rural Development",
   "status": "prohibited",
   "quote": "any use not expressly listed as permitted or conditionally permitted is also prohibited",
   "code_section": "2.2.3.E; Table 2.2-1",
   "conditions": "Table 2.2-1 lists no restaurant or drive-through use for agriculture/residential districts.",
   "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
   "read_on": "2026-11-23"
  }
 ],
 "profile": {
  "official_name": "Town of San Tan Valley, Arizona",
  "code_title": "Town of San Tan Valley Zoning Ordinance (Ordinance No. 2026-04)",
  "code_last_amended": "Adopted June 1, 2026 (text dated 5/29/2026); effective July 1, 2026",
  "zoning_map_url": "https://drive.google.com/file/d/1DY42069gMEk6NHRFffeDQ57FytOSNdy7/view",
  "planning_office": {
   "name": "Town of San Tan Valley Community Development Department",
   "url": "https://www.santanvalley.gov/"
  },
  "drive_thru_summary": "The Town lists 'Drive Through' as its own use separate from 'Restaurant'. Both are permitted outright only in C-3 Regional Commercial and I-2 Light Industrial; C-1, C-2, I-1 and I-3 need a conditional use permit from the Town Council after a P&Z hearing. Every drive-through must meet Sec. 3.1.10, and one within 500 ft of a residential district needs a use permit anywhere.",
  "drive_thru_stacking": "Sec. 3.1.10: restaurants 4 queuing spaces per window (2 per lane for double lanes), plus 40 ft from lane entry to menu board and 100 ft from order point to pickup window; 12-ft lanes. Sec. 4.2.11.F separately lists 3 spaces behind the menu board and 3 behind the window for drive-through restaurants (the two tables differ; the stricter governs in practice). Town Engineer may require a queuing study.",
  "parking_restaurant": "Full service: 1 space per 50 sq ft patron area + 1 per 400 sq ft outdoor seating; limited service: 1 per 75 sq ft patron area + 1 per 400 sq ft outdoor seating (Sec. 4.2.4).",
  "signs": "Sec. 4.4.9.D: each drive-through lane may have one board without and one with a call box, at least 45 ft from the street line, max 6 ft tall, up to 48 sq ft per drive-through (not counted toward the lot's sign total), board face not visible from the street; directional drive-through signs up to 3 sq ft and 4 ft tall.",
  "approvals": [
   {
    "type": "Conditional Use Permit",
    "who_decides": "Town Council after Planning and Zoning Commission recommendation",
    "steps": "Pre-application meeting; application with site plan, 600-ft ownership list and map (site plan reviewed concurrently); optional neighborhood meeting if staff require; staff report; P&Z public hearing; Council meeting (hearing if written objection)",
    "section": "6.7; Table 6.3-1",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   },
   {
    "type": "Site Plan Review",
    "who_decides": "Zoning Administrator",
    "steps": "Administrative review against the ordinance",
    "section": "6.11; Table 6.3-1",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   }
  ],
  "districts": {
   "C-1": {
    "name": "Neighborhood Commercial",
    "setbacks": "Front 20 ft, side 5 ft (15 ft next to residential), rear 20 ft (30 ft next to residential); 15 ft for street-facing parking",
    "max_height": "30 ft",
    "max_coverage": "60%",
    "restaurant": "conditional",
    "retail": "by_right",
    "gas_station": "prohibited",
    "car_wash": "prohibited",
    "section": "Tables 2.3-1, 2.3-2",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   },
   "C-2": {
    "name": "Community Commercial",
    "setbacks": "Front 20 ft, side 5 ft (15 ft next to residential), rear 20 ft (30 ft next to residential)",
    "max_height": "40 ft",
    "max_coverage": "60%",
    "restaurant": "by_right",
    "retail": "by_right",
    "gas_station": "by_right",
    "car_wash": "conditional",
    "section": "Tables 2.3-1, 2.3-2",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   },
   "C-3": {
    "name": "Regional Commercial",
    "setbacks": "Front 20 ft, side 5 ft (25 ft next to residential), rear 20 ft (30 ft next to residential)",
    "max_height": "45 ft",
    "max_coverage": "80%",
    "restaurant": "by_right",
    "retail": "by_right",
    "gas_station": "by_right",
    "car_wash": "conditional",
    "section": "Tables 2.3-1, 2.3-2",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   },
   "I-1": {
    "name": "Office/Business Park",
    "setbacks": "Front 20 ft, side 25 ft next to residential, rear 25 ft",
    "max_height": "35 ft",
    "max_coverage": "60%",
    "restaurant": "by_right",
    "retail": "prohibited",
    "gas_station": "by_right",
    "car_wash": "conditional",
    "section": "Tables 2.4-1, 2.4-2",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   },
   "I-2": {
    "name": "Light Industrial",
    "setbacks": "Front 20 ft, side 25 ft next to residential, rear 10 ft (25 ft next to residential)",
    "max_height": "55 ft (more with extra setback)",
    "max_coverage": "80%",
    "restaurant": "by_right",
    "retail": "by_right",
    "gas_station": "by_right",
    "car_wash": "by_right",
    "section": "Tables 2.4-1, 2.4-2",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   },
   "I-3": {
    "name": "Heavy Industrial",
    "setbacks": "Front 20 ft, side 25 ft next to residential, rear 10 ft (25 ft next to residential)",
    "max_height": "65 ft (more with extra setback)",
    "restaurant": "conditional",
    "retail": "conditional",
    "gas_station": "prohibited",
    "car_wash": "prohibited",
    "section": "Tables 2.4-1, 2.4-2",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   }
  },
  "overlays": [
   {
    "name": "PAD Overlay (legacy Pinal County Planned Area Developments)",
    "effect": "Prior county PAD approvals keep governing use and development until rezoned; no new PADs",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   },
   {
    "name": "Middle Housing Overlay",
    "effect": "Allows duplex to fourplex and townhomes near the Central Business District; residential only",
    "source_url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view"
   }
  ],
  "sources": [
   {
    "title": "Town of San Tan Valley Zoning Ordinance, adopted 6-1-2026 (PDF)",
    "url": "https://drive.google.com/file/d/1BcHBddfT03eMCg9L7nvQmP-rYAanGaOv/view",
    "read_on": "2026-11-23"
   },
   {
    "title": "Town zoning layer Zoning_SanTanValley_Merge (FeatureServer/9)",
    "url": "https://services7.arcgis.com/taxrXv3wELVrPFY3/arcgis/rest/services/SanTanValley_ZoningOrd_gdb/FeatureServer/9",
    "read_on": "2026-11-23"
   },
   {
    "title": "SanTanValley.com: Town adopts first zoning ordinance and town code (links the PDFs)",
    "url": "https://santanvalley.com/news/santanvalleynews/san-tan-valley-news/san-tan-valley-adopts-first-zoning-ordinance-and-town-code-ahead-of-july-1-launch",
    "read_on": "2026-11-23"
   },
   {
    "title": "Govly: Town Council special meeting June 1, 2026",
    "url": "https://app.govly.com/public/meetings/56241",
    "read_on": "2026-11-23"
   }
  ],
  "verified": {
   "on": "2026-11-23",
   "by": "opus",
   "checked": 15,
   "corrected": 0,
   "notes": "Read directly in adopted ordinance PDF: Table 2.1-1 district list, Table 2.2-1 (residential, no restaurant/drive-through), Table 2.3-1 (C-1/C-2/C-3), Table 2.4-1 (I-1/I-2/I-3), Table 2.5-1 (POS/FD), Sec. 3.1.10, 4.2.4, 4.2.11.F, 4.4.9.D, 6.7. Town code is the Town's own new ordinance (drafted by Michael Baker), not the county code; county districts were mapped to Town equivalents. Confidence capped at medium: the adopted PDF was read from a copy linked by a local news site, not from the Town website (which could not be opened); confirm against the Town-posted ordinance."
  }
 },
 "fees": null,
 "note": "Summary of the public zoning code with links to each source. Not legal advice; confirm with the planning office."
}